Makita AG090, AG125 instruction manual Maintenance of compressor, air set and air hose

Page 16

Maintenance of compressor, air set and air hose

After operation, always drain the compressor tank and the air filter. If moisture is allowed to enter the tool, it may result in poor performance and possible tool failure.

Check regularly to see if there is sufficient pneumatic oil in the oiler of the air set. Failure to maintain sufficient lubrica- tion will cause O-rings to wear quickly.

Keep the air hose away from heat (over 60°C, over 140°F), away from chemicals (thinner, strong acids or alkalis). Also, route the hose away from obstacles which it may become dangerously caught on during operation. Hoses must also be directed away from sharp edges and areas which may lead to damage or abrasion to the hose.

To maintain product SAFETY and RELIABILITY, mainte- nance and repairs should be performed by Makita Authorized or Factory Service Centers, always using Makita replace- ment parts.

16

Image 16
Contents Air Nailer Specifications Read ALL Instructions Page Shutter Nail guide Trigger Adjuster Nail Thump ING Label Selecting compressor Selecting air hoseLubrication Selecting nailsConnecting air hose Adjusting depth of nailingLoading nailer Nailing with one or two impacts OperationNailing in metal plate holes Air exhaust Jammed nailerHook NailsMaintenance Maintenance of nailerMaintenance of compressor, air set and air hose Makita U.S.A., Inc Mail this Portion Factory Service Centers Makita Limited ONE Year Warranty