DeVillbiss Air Power Company MG-NS2X4A, NBSNC2X4, NF2502X4, SNC1002X4 Clearing a JAM from the Tool

Page 13

CLEARING A JAM FROM THE TOOL

Disconnect tool from air compressor before adjusting, clearing jams, servicing, relocating and during non-operation.

FASTENER JAMMED IN FASTENER DISCHARGE AREA:

1.Disconnect tool from air hose.

2.NF2502X4, NB1252X4, NB2002X4, NBSNC2X4

Release the magazine latch to open the magazine.

Magazine

Latch

SNC1002x4

Pull feeder shoe back into "locked" position.

Feeder

3.Remove fasteners from magazine.

4.NF2502X4, SNC1002X4, NB2002X4, and NB1252X4

Lift nose cover latch to unlatch and re- move driver guide cover.

Nose

Cover

Latch

NBSNC2x4

Loosen the screws on the driver guide cover and then remove the driver guide cover.

5. Using pliers remove fasteners.

6.NF2502X4, NB1252X4, NB2002X4, and SNC1002X4

Replace nose cover and latch into place.

NBSNC2X4 Replace nose cover.

7.Reload fasteners into magazine. Refer to Loading the Tool section in this manual.

PAGE 13

Image 13
Contents Nailer/Stapler Specifications Table of Contents ONE Year from Date of Purchase Risk of explosion Risk of head injury Risk from flying objects Do not Over Lubricate AIR Tool Lubrication and MaintenanceRegulator Air Flow Oiler Filter Recommended HOOK-UP Contact Trip Safety Mechanism2X4 Contractor Series Operating a Contact Trip Tool Loading the ToolLoading the Tool Operating the Tool Fastener Jammed in Fastener Discharge Area Clearing a JAM from the ToolFastener JAM Inside Magazine Problem Cause Solution Troubleshooting GuideAwsc Awsc Troubleshooting Guide contdNF2502X4 Safety Glasses NPT Inlet Plug AC100 Finish Nail FastenersLubricating OIL Combination Crescent Finish Wrench NailerSNC1002X4 Safety Glasses NarrowCrown Allen Inlet Plug Narrow Staple Lubricating Wrenches CrownAC100NAILER NB2002X4Brad Nailer NB1252X4Lubricating Narrow Crown Staple Brad Nail Fasteners OIL NBSNC2X4SNC1002X4 and NB1252X4 Repair Kits AvailableNBSNC2X4 Nailer/Stapler Warranty