COMPRESSOR FEATURES

OIL LUBRICATION: Oil lubricated direct drive pump with cast-iron cylinder for durability.

OIL FILL SIGHT GLASS: Located on the face of the crankcase, the oil fill sight glass provides a convenient way to check the oil fill level within the pump. The oil level must be checked prior to each use to ensure proper fill level.

DO NOT OPERATE THE COMPRESSOR WITHOUT LUBRICANT, OR WITH LOW LUBRICATION LEVEL. THE MANUFACTURER IS NOT

RESPONSIBLE FOR DAMAGE CAUSED TO THE COMPRESSOR DUE TO OPERATION WITHOUT PROPER LUBRICATION.

3AUTOMATIC ON/OFF PRESSURE SWITCH: This compressor is equipped with an automatic ON/OFF pressure switch. The compressor will only run when the switch is in the ON/AUTO position. Once the tank has reached the desired preset pressure (“cut-out” pressure), the pump motor will automatically shut off. While the switch is in the ON/AUTO position, the pump motor will automatically turn back on once the pressure in the tank drops below the minimum preset pressure (“cut-in” pressure).

DO NOT LEAVE THE COMPRESSOR UNATTENDED WHILE THE POWER SWITCH IS IN THE ON/AUTO POSITION.

UNPLUG POWER CORD WHEN NOT IN USE.

4AIR TANK PRESSURE GAUGE: The tank pressure gauge provides a reading of the air pressure inside of the compressor tank.

5PRESSURE REGULATOR: The regulator allows you to select the amount of air pressure that is output through the air hose into tools and accessories. Turn the pressure regulator knob clockwise to increase discharge pressure, and counter clockwise to decrease discharge pressure. Please refer to the air delivery requirements of your tools for the proper pressure settings.

NOTICE: Be careful not to overtighten pressure regulator knob when it “bottoms out” as this may damage pressure regulator.

6OUTLET PRESSURE GAUGE: The outlet pressure gauge provides a reading of the air pressure at the outlet side of the regulator. This pressure is controlled by the pressure regulator and is always less than or equal to the air tank pressure.

7AIR OUTLET VALVE: The air outlet Valve is attached to the pressure regulator and can be open or closed to allow for shut off air flow. It is recommended to attach a quick connect air coupler (not included) for quick connect and disconnection of air hose.

8SAFETY RELIEF VALVE: This compressor is equipped with a safety relief valve that is designed to prevent system failures by relieving pressure from the system when the air pressure reaches a predetermined level. The safety relief valve is preset by the manufacturer. DO NOT attempt to modify or remove the safety relief valve.

9AIR TANK DRAIN VALVE: Moisture is produced whenever air is compressed. It is critical to drain water from the air tank on this compressor frequently. If unit is used only occasionally, tank should be drained after each use and prior to the next use. To drain the tank, slowly open the tank drain fitting by turning clockwise. Once all moisture has drained out, close the fitting securely. NOTE: Air tank will not pressurize while drain valve is open.

10AIR INTAKE FILTER: This compressor is equipped with an externally accessible air intake filter that is designed to clean air coming into the pump. The filter element is easily removed for periodic cleaning. Use compressed air to blow loose dirt and debris from the paper filter element and reinstall. Replace paper filter element when necessary.

A dirty air filter will reduce air compressor performance and can lead to product failure.

11MANUAL THERMAL OVERLOAD SWITCH: The electric motor has a manual thermal overload protector. If the motor overheats for any reason, the thermal overload protector will shut off the motor. Turn pressure switch to the “off” position and wait for unit to cool before pushing the reset button and restarting the compressor. NOTICE: This air compressor is designed for household use only and is not intended to operate heavy-duty air tools. If your application’s demands exceed the capacity of this air compressor, a larger air compressor that is matched to your application is recommended. If the unit shuts down again, please call the consumer helpline at 1-800-423-3598 for assistance.

12CARRY HANDLE: Convenient handle for easy transport.

8

Image 10
Contents Twin Stack AIR Compressor Table of Contents Specifications Introduction Safety AlertUnpacking & Inspection General Safety Warnings Safety WarningsDrain Liquid from AIR Tank Daily Installation and Location Grounding InstructionsExtension Cord Length Wire Size AWG Compressor FeaturesCompressor Features Compressor Features Pump Lubrication Assembly InstructionsAssembly Check Inspection CheckStartup Initial Setup / BREAK-IN ProcedureMaintenance OperationShutdown and Storage When Performing ANY Maintenance or ServiceMaintenance Checklist OIL ChangeChecking AIR Filter Element Checking Safety Relief ValveMoisture in Compressed AIR Troubleshooting Guide Or air accessory Motor/pressure switch releaseAir leaks from safety relief Air continues to leak atParts List Description QTY Parts Diagram Warranty Disclaimers Factory RE-MANUFACTURED 30 DAY WarrantyWarranty Performance ExclusionsLimitations on Warranty Disclaimers Limitation Of LiabilityCopyright 2006, Alltrade Tools LLC REV.1