DeVillbiss Air Power Company SB-2-540 operation manual

Page 5

SB-2-540

Page 5

 

 

 

 

 

 

1.Remove Adjusting Knob (7), Spring (8), and Needle (9).

4.Remove Valve (11).

7.Push out the Front Airvalve Seal with a finger.

2.Loosen Housing (10).

5.Using Service Tool SPN-7, engage groove behind the Valve Seat.

8.Turn the Gun upside down and let the Seal fall out.

3.Remove Housing (10) and Airvalve Spring.

6.Remove Valve Seat.

9.Fit New Front Seal to Service Tool.

10.Fit new Seal to gunbody and press firmly to ensure Seal is engaged.

11.Fit New Valve Seat to Service Tool. Groove must face outwards.

Image 5
Contents TRANS-TECHGRAVITY Feed Spraygun EC Declaration of Conformity DescriptionFire and Explosion Personal Protective EquipmentExample COM-G510G-14-02 SB-2-540Description Part Number OptionsInstallation SpecificationPreventative Maintenance Replacement of PartsSB-2-540 SB-2-540 Troubleshooting Condition Cause Correction Condition Cause Correction Accessories Página 10 SB-2-540 Ejemplo COM-G510G-14-02 SB-2-540 PáginaNúmero Descriptión De Pieza OpcionesPágina 12 SB-2-540 SB-2-540 Página Página 14 SB-2-540 La parte superior Patrón pesado enInferior El lado derechoCondición Causa Corrección Localización Y Reparación DE Problemas continuaráPágina 16 SB-2-540 Accesorios SB-2-540 Notas Canada Technical Service Office This product is covered by DeVilbiss 1 Year Limited Warranty