DeVillbiss Air Power Company D23757 manual Storage, To Replace Regulator

Page 16

To Replace Regulator

1.Release all air pressure from air tank. See “To Drain Tank” in the Maintenance section.

2.Unplug outfit.

3.Using an adjustable wrench remove the gauges and quick connect or hose adapter from the regulator.

4.Remove the regulator.

5.Apply pipe sealant tape to the nipple on the standpipe or regulator.

6.Assemble the regulator and orient as shown.

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

7.Reapply pipe sealant to gauges and quick connect.

8.Reassemble gauges and quick connect. Orient gauges to read correctly. Tighten quick connect with wrench.

Regulator

Arrow

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary.

2.Set the On/Auto/Off lever to “OFF”.

3.Turn the regulator counterclockwise and set the outlet pressure to zero.

4.Remove the air tool or accessory.

5.Pull ring on safety valve allowing air to bleed from the tank until tank pres- sure is approximately 20 psi. Release safety valve ring.

6.Drain water from air tank by opening drain valve on bottom of tank.

Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a

risk of air tank rupture.

7.After the water has been drained, close the drain or drain valve.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

8.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped)

9.Store the air compressor in a clean and dry location.

D23757

16- ENG

Image 16
Contents OPERATOR’S Manual Safety Guidelines Definitions Table of ContentsImportant Safety Instructions Hazard Attachments & Accessories Hazard What can Happen HOW to Prevent IT Fire, Inhalation, Damage to Vehicle Surfaces Accessories ON-RECEIPT InspectionGlossary Duty CycleAssembly for Pancake units Assembly for Tank unitsInstallation Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionOperation Know Your Air Compressor Description of OperationBefore Starting Before Each Start-UpMaintenance How to StartTo Check Safety Valve Customer ResponsibilitiesService and Adjustments To Replace or Clean Check ValveStorage To Replace RegulatorTroubleshooting Problem Cause CorrectionPressure reading Problem Cause Correction Limited Warranty