IMPORTANT SAFETY INSTRUCTIONS

Save these instructions

Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.

HAZARD

WARNING: Risk of explosion or fire

What Could Happen

It is normal for electrical contacts within the motor and pressure switch to spark.

If electrical sparks from compressor come into contact with flammable vapors, they may ignite, causing fire or explosion.

Restricting any of the compressor venti- lation openings will cause serious over- heating and could cause fire.

Unattended operation of this product could result in personal injury or prop- erty damage. To reduce the risk of fire, do not allow the compressor to operate unattended.

How To Prevent It

Always operate the compressor in a well ventilated area free of combustible materials, gasoline, or solvent vapors.

If spraying flammable materials, locate compressor at least 20 feet away from spray area. An additional length of hose may be required.

Store flammable materials in a secure location away from compressor.

Never place objects against or on top of compressor. Operate compressor in an open area at least 12 inches away from any wall or obstruction that would restrict the flow of fresh air to the ventila- tion openings.

Operate compressor in a clean, dry well ventilated area. Do not operate unit indoors or in any confined area.

Always remain in attendance with the product when it is operating.

Always disconnect electrical power by moving pressure switch lever to the off position and drain tank daily or after each use.

3- ENG

D23757

Image 3
Contents OPERATOR’S Manual Table of Contents Safety Guidelines DefinitionsImportant Safety Instructions Hazard Attachments & Accessories Hazard What can Happen HOW to Prevent IT Fire, Inhalation, Damage to Vehicle Surfaces Duty Cycle AccessoriesON-RECEIPT Inspection GlossaryAssembly for Tank units Assembly for Pancake unitsLocation of the Air Compressor InstallationVoltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation OperationBefore Each Start-Up Before StartingCustomer Responsibilities MaintenanceHow to Start To Check Safety ValveTo Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator StorageProblem Cause Correction TroubleshootingPressure reading Problem Cause Correction Limited Warranty