DeVillbiss Air Power Company D26368 Service and Adjustments, To Replace or Clean Check Valve

Page 18

6.After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.

Air Filter Inspection and Replacement

Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed. Allow compressor

to cool prior to servicing.

Keep the air filter clean at all times. Do not operate the air compressor with the air filter removed.

A dirty air filter will not allow the compressor pump to operate at full capacity. Before you use the compressor pump, check the air filter to be sure it is clean and in place.

If it is dirty, replace it with a new filter. On some models,the filter may be removed by using a pair of needle nose pliers or a screwdriver. Pull or pry out the old filter and carefully clean the filter area. Push in the new air filter.

Air Compressor Pump Intake and Exhaust Valves

Once a year have a Trained Service Technician check the air compressor pump intake and exhaust valves.

SERVICE AND ADJUSTMENTS

Unit cycles automatically when power is on. When doing Maintenance, you may be exposed to voltage sources,

compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.

Before servicing:

Unplug or disconnect electrical supply to the air compressor. Bleed tank of pressure.

Allow the air compressor to cool.

To Replace or Clean Check Valve

1.Release all air pressure from air tank. See “To Drain Tank” in the Maintenance section.

2.Unplug compressor.

3.(if equipped) Remove the regulator ring and

remove the console cover.

Regulator

Cover

Ring

4. (if equipped) Remove shrouds.

 

 

 

5. Using an adjustable wrench, loosen outlet tube nut at air tank and pump. Carefully move outlet tube away from check valve.

6.Using an adjustable wrench, loosen pressure relief tube nut at air tank and pressure switch. Carefully move pressure relief tube away from check valve.

D26368

18- ENG

Image 18
Contents OPERATOR’S Manual Table of Contents Safety Guidelines DefinitionsImportant Safety Instructions Hazard Attachments & Accessories Hazard What can Happen HOW to Prevent IT Fire, Inhalation, Damage to Vehicle Surfaces Glossary AccessoriesON-RECEIPT Inspection Duty CycleAssembly Assembly for Pancake unitsSome horizontal units are equipped with a console Assembly for Vertical units Assembly for Horizontal units Installation Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionOperation Know Your Air Compressor Description of OperationHow to Stop Before StartingHow to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankTo Replace or Clean Check Valve Service and AdjustmentsAir Filter Inspection and Replacement Air Compressor Pump Intake and Exhaust ValvesTo Replace Regulator Storage Troubleshooting Problem Cause CorrectionPressure reading Check wiring connection Limited Warranty