DeVillbiss Air Power Company D26368 manual Storage

Page 20

6.Apply pipe sealant tape to the nipple.

7.Assemble the regulator and orient as shown.

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

Regulator

Regulator

Arrow

8.Reapply pipe sealant to outlet pressure gauge and quick connect.

9.Reassemble outlet pressure gauge and quick connect. Orient outlet pressure gauge to read correctly. Tighten quick connect with wrench.

10.(if equipped) Replace shrouds and console.

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary.

2.Set the On/Auto/Off lever to “OFF”.

3.Turn the regulator counterclockwise and set the outlet pressure to zero.

4.Remove the air tool or accessory.

5.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

6.Drain water from air tank by opening drain valve on bottom of tank.

Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a

risk of air tank rupture.

7.After the water has been drained, close the drain or drain valve.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

8.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped)

9.Store the air compressor in a clean and dry location.

D26368

20- ENG

Image 20
Contents OPERATOR’S Manual Important Safety Instructions Table of ContentsSafety Guidelines Definitions Hazard Attachments & Accessories Hazard What can Happen HOW to Prevent IT Fire, Inhalation, Damage to Vehicle Surfaces Accessories ON-RECEIPT InspectionGlossary Duty CycleSome horizontal units are equipped with a console AssemblyAssembly for Pancake units Assembly for Vertical units Assembly for Horizontal units Installation Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionOperation Know Your Air Compressor Description of OperationHow to Stop Before StartingHow to Start Before Each Start-UpMaintenance To Check Safety ValveCustomer Responsibilities To Drain TankService and Adjustments Air Filter Inspection and ReplacementTo Replace or Clean Check Valve Air Compressor Pump Intake and Exhaust ValvesTo Replace Regulator Storage Troubleshooting Problem Cause CorrectionPressure reading Check wiring connection Limited Warranty