GROUNDING INSTRUCTIONS

RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing

an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances.

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT

USE AN ADAPTER.

Grounding

Pin

120 Volt U.S.A. Plug

Grounding

Pin

240 Volt U.S.A. Plug

When used outside of the United States of America a conversion kit may be required for local use.

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician. Repairs to the cord set or plug MUST be made by a qualified electrician.

Extension Cords

Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed. If an extension cord must be used, be sure it is:

a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product

in good condition

no longer than 50 feet

14 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 12 AWG, 10 AWG, and 8 AWG may also be used. DO NOT USE 16 OR 18 AWG.)

A08200

10- ENG

Image 10
Contents Oil-Free Air Compressor Death or serious injury Or moderate injury Safety Guidelines DefinitionsImportant Safety Instructions Death or serious injuryHazard Always remain in attendance withAttachments & Accessories What Could HappenTo human consumption Electricity. Like any other electricallyRepairs attempted by unqualified Your specific applicationResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsKeep children away from the air compressor at all times Equip area of operation with a fire extinguisherGlossary SpecificationsAccessories Duty CycleAssembly for Tank units InstallationLocation of the Air Compressor Grounding Instructions Extension CordsVoltage and Circuit Protection Regulator OperationKnow Your Air Compressor Description of Operation Check ValveBefore Starting Before Each Start-UpTo Check Safety Valve MaintenanceHow to Start Customer ResponsibilitiesOutlet Tube Service and AdjustmentsTo Replace or Clean Check Valve Check Valve Screwdriver Open position nothing is visibleStorage To Replace RegulatorTroubleshooting Problem Cause CorrectionBeing used Problem Cause Correction Limited Warranty