Delta CP503 Maintenance, How to Start, Customer Responsibilities, To Check Safety Valve

Page 14

How to Start:

1.Turn the On/Auto/Off lever to "ON/AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place. The compressor is ready for use.

NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.

 

MAINTENANCE

Customer Responsibilities

 

 

 

 

 

Before each use

Daily or after

 

each use

 

 

Check Safety Valve

 

Drain Tank

 

To Check Safety Valve

If the safety valve does not work properly, over- pressurization may occur, causing air tank

rupture or an explosion. Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.

To Drain Tank

1.Set the On/Auto/Off lever to "OFF".

2.Pull the regulator knob out and turn clockwise to set the outlet pressure to zero.

3.Remove the air tool or accessory.

4.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

5.Drain water from air tank by opening drain valve (counter-clockwise) on bottom of tank.

Water will condense in the air tank. If not drained, water will corrode and weaken the air tank

causing a risk of air tank rupture.

6.After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

A08200

14- ENG

Image 14
Contents Oil-Free Air Compressor Death or serious injury Or moderate injury Safety Guidelines DefinitionsImportant Safety Instructions Death or serious injuryHazard Always remain in attendance withAttachments & Accessories What Could HappenTo human consumption Electricity. Like any other electricallyRepairs attempted by unqualified Your specific applicationResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsKeep children away from the air compressor at all times Equip area of operation with a fire extinguisherGlossary SpecificationsAccessories Duty CycleLocation of the Air Compressor InstallationAssembly for Tank units Grounding Instructions Extension CordsVoltage and Circuit Protection Regulator OperationKnow Your Air Compressor Description of Operation Check ValveBefore Starting Before Each Start-UpTo Check Safety Valve MaintenanceHow to Start Customer ResponsibilitiesOutlet Tube Service and AdjustmentsTo Replace or Clean Check Valve Check Valve Screwdriver Open position nothing is visibleStorage To Replace RegulatorTroubleshooting Problem Cause CorrectionBeing used Problem Cause Correction Limited Warranty