Emerson IP2063/SI manual Instructions specific to hazardous area installations

Page 2

GB

Instructions specific to hazardous area installations

Model numbers covered: ***S*U*H*** ('*' indicates options in construction, function and materials.) The following instructions apply to equipment covered by certificate number TRL 03ATEX21023X:

1.The equipment may be used with flammable gases and vapours with apparatus groups IIA, IIB & IIC, and with temperature classes T1, T2, T3, T4 & T5.

Note: The enclosure may be at the higher of the process or ambient temperature.

2.Installation of this equipment shall be carried out by suitably trained personnel, in accordance with the applicable code of practice.

3.The equipment is not intended to be repaired by the user and is to be replaced by an equivalent certified unit. Repairs should only be carried out by the manufacturer or approved repairer.

4.The apparatus electronics is only certified for use in ambient temperatures in the range of -40ºC to +85ºC for T4 or -40ºC to +40ºC for T5. It should not be used outside this range.

5.If the equipment is likely to come into contact with aggressive substances, it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised.

Aggressive Substances: - e.g. acidic liquids or gases that may attack metals or solvents that may affect polymeric materials.

Suitable Precautions: - e.g. regular checks as part of routine inspections or establishing from the material's data sheet that it is resistant to specific chemicals.

6.The cable screen may have been internally connected to the metal housing of the equipment.

7.Technical Data:

(a) Materials of construction: Refer to Part numbering identification chart.

(b) Coding:

II 1 G,

T4 (-40°C Ta +85°C)

 

EEx ia IIC

 

 

T5 (-40°C Ta +40°C)

(c) Electrical:

Input parameters: Ui: +16.27V, Ii: 205mA, Pi: 0.63W, Ci: 8nF, Li: 0mH

(d) Pressure: Must not exceed the rating of the coupling/flange fitted.

8.Special conditions for safe use:

(a) The sensor may not meet the requirements of EN50020: 2002 clause 6.4.12 (Isolation of circuits from earth or frame). Therefore, the sensor shall only be connected via a galvanically isolated source, or an adjacent amplifier as described below.

(b) The sensor when used in ATEX applications shall only be connected to an Adjacent Amplifier certified under EC type examination certificate TRL03ATEX21033X or TRL03ATEX21035X.

(c) The sensor shall be installed such that it shall not exceed the Class 3M8/4M8 level of vibration as defined by IEC60721.

(d) If the enclosure is made of an alloy or plastic material, the following precautions must be observed:

(i) The metallic alloy used for the enclosure material may be at the accessible surface of this equipment; in the event of rare accidents, ignition sources due to impact and friction sparks could occur. This shall be considered when the Sensor is being installed in locations that specifically require group II, category 1G equipment.

(ii) Under certain extreme circumstances, the non-metallic parts incorporated in the enclosure of the Sensor may generate an ignition-capable level of electrostatic charge. Therefore, when they are used for applications that specifically require group II, category 1 equipment, the Sensor shall not be installed in a location where the external conditions are conducive to the build-up of electrostatic charge on such surfaces. Additionally, the Sensor shall only be cleaned with a damp cloth.

Please note that the safety instructions and certificates in this publication have been translated from English (United Kingdom).

Page 2

IP2063/SI

Image 2
Contents Electrosensor and Electropulse Sensors Instructions specific to hazardous area installations IP2063/SI EEx ia IIC IP2063/SI Anleitung zur Installation in gefährlicher Umgebung IP2063/SI EEx ia IIC IP2063/SI EEx ia IIC IP2063/SI EEx ia IIC IP2063/SI EEx ia IIC IP2063/SI FIN Erityisohjeet asennuksiin vaarallisilla alueilla IP2063/SI Ειδικες οδηγιες για εγκαταστασεις σε επικινδυνες περιοχες IP2063/SI Instruktioner for installationer i risikoområder IP2063/SI PL Instrukcja instalacji w strefach zagroĪonych wybuchem IP2063/SI Instruções específicas para áreas perigosas IP2063/SI IP2063/SI IP2063/SI Emerson Process Management Mobrey Measurement Rosemount Inc

IP2063/SI, Electrosensor and Electropulse Sensors specifications

Emerson Electrosensor and Electropulse Sensors, specifically the IP2063/SI model, represent a significant advancement in the field of industrial sensing and automation technologies. These sensors are designed to enhance the efficiency and precision of various applications, particularly in environments where accurate measurements are critical.

One of the key features of the IP2063/SI model is its robust and versatile design, which allows it to perform effectively in harsh operating conditions. With an IP67 rating for ingress protection, the sensor is fully dust-tight and can withstand immersion in water, making it suitable for use in wet and demanding environments like food processing, wastewater management, and chemical manufacturing.

The IP2063/SI employs advanced electropulse technology, which provides high sensitivity and rapid response times. This technology allows for precise monitoring of parameters such as pressure, temperature, and flow, ensuring optimal functionality across diverse applications. The sensor’s ability to deliver accurate and real-time data helps industries to maintain better control over their processes, thereby enhancing productivity and reducing downtime.

Another notable characteristic of the IP2063/SI is its compatibility with a wide range of control systems. The sensor can easily integrate with existing infrastructure, facilitating seamless upgrades to automation systems without significant overhauls. This compatibility is further complemented by its communication capabilities, which can include various protocols to interface with other devices, enhancing data visibility and operational insight.

Reliability is another hallmark of the Emerson Electrosensor's IP2063/SI. Engineered with durability in mind, it features high-quality components that minimize the likelihood of failures, leading to extended service life. Predictive maintenance features enable users to anticipate potential issues before they escalate, ensuring that operations remain uninterrupted.

In summary, the Emerson Electrosensor and Electropulse Sensors, IP2063/SI model, stand out for their robust design, advanced electropulse technology, superior compatibility, and reliability. The combination of these features makes it an invaluable tool for industries aiming to improve their operational efficiencies and achieve greater accuracy in monitoring and control processes. As industries continue to focus on automation and precision, products like the IP2063/SI will play a crucial role in driving innovation and productivity.