Emerson 2 user manual Refrigeration system parts, 3 ton units

Page 36

 

 

 

 

 

 

 

 

Parts

Table 16 Refrigeration system parts, 3 ton units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ET035S

ET035N

ET035M

ET036P

ET036Y

ET036A

 

 

 

 

 

 

 

 

 

Figure

Part Name/

Part #

220-240V

200-240V

380-415V

208-230V

208-230V

460V

No.

Description

1Ph 50Hz

3Ph 50Hz

3Ph 50Hz

1Ph 60Hz

3Ph 60Hz

3Ph 60Hz

 

Run capacitor, recip comp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-7

Cap. 40μF, 370V

1A19538P1

1

N/A

N/A

1

N/A

N/A

 

Run capacitor, scroll comp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-7

Cap. 40μF, 370V

1A19538P1

 

N/A

N/A

1

N/A

N/A

 

 

 

 

 

 

 

 

 

7-7

Cap. 50μF, 370V

C15-0090

1

N/A

N/A

 

N/A

N/A

 

Compressors, reciprocating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-5

Comp. 220/240-1-50

159124P1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-5

Comp. 200/240-3

159212P2

 

1

 

 

1

 

 

 

 

 

 

 

 

 

 

7-5

Comp. 380/460-3

159212P3

 

 

1

 

 

1

 

 

 

 

 

 

 

 

 

7-5

Comp. 200/230-1

159212P1

 

 

 

1

 

 

 

Compressors, scroll

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-6

Comp. 220/240-1

148221P2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-6

Comp. 208/230-3

148325P1

 

1

 

 

1

 

 

 

 

 

 

 

 

 

 

7-6

Comp. 380/460-3

148325P2

 

 

1

 

 

1

 

 

 

 

 

 

 

 

 

7-6

Comp. 200/230-1

159149P1

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

Pressure switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High pressure - 400 psi

159482P1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

Fan cycle switch - 170 psi

159483P1

 

Optional feature—quantity 1 (as required)

 

 

 

 

 

 

 

 

Low pressure - 35 psi

159484P1

 

Optional feature—quantity 1 (as required)

 

 

 

 

 

 

 

 

Adj Pr Sw for Adj FCC

P67-0110

 

Optional feature—quantity 1 (as required)

 

 

 

 

 

 

 

 

 

 

 

Filter drier

127185P1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

7-10

Condenser coil - 1.5/3T

159118P1

1

1

1

1

1

1

10-1

Evaporator coil - 3T

159180P1

1

1

1

1

1

1

10-1

Thermal expansion valve - 3T

1C19507P2

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

Crankcase Heaters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-9

Strap style 240V scrolls

132102P1

1

1

 

1

1

 

 

 

 

 

 

 

 

 

 

7-9

Strap style 480V scrolls

132102P2

 

 

1

 

 

1

 

 

 

 

 

 

 

 

 

8-1

Well style (recips. only)

1A17648P1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

8-2

Retainer plug

159136P1

1

1

1

1

1

1

15-1

Soft start kit

1C19540P1

 

Optional feature—quantity 1 (as required)

 

 

 

 

 

 

 

 

 

 

30

Image 36
Contents Liebert InteleCool2 Page Table of Contents Specifications Troubleshooting Maintenance Inspection Checklist PartsFigures ET 0 36 H R P F B T Standard Features GeneralOptional Features Accessories Ancillary ComponentsUnit Installation PreparationRoom Preparation Location ConsiderationsMounting dimensional data See below for keys to dimensionsPiping Connections Power Connections DuctingElectrical Connections Control ConnectionsLiebert Thermostat Tele2Installation AdjustmentOutside Air Damper Optional Economizer OptionalChecklist for Complete Installation START-UP Procedure Compressorized Cooling Refrigeration systemEconomizer Cooling Optional Heating OptionalEnthalpy Sensor ActuatorRemote Control Interface Unit ControlsHigh Pressure Standard Refrigeration Control OptionsAnti-Short Cycle Timer Standard Common Alarm OptionalPack1 package Pack2 packageFilters Blower PackageHeat Refrigeration SystemCompressor Thermostatic Expansion ValveAir-Cooled Condenser Mechanical FailureCompressor Replacement Electrical FailurePressure information Design Minimum MaximumPsig kPa Psig kPA Dimensional Data InteleCool2 dimensional data in. mmTechnical Data Technical data, 60 HzCFM m 3/hr 490 22280F DB/19.4C 67F WB indoor ambient kW Btuh Outdoor ambient M3/hr CFMTechnical data, 50 Hz Ambient kW BtuhHr CFM Optional heater capacity, 60 Hz Optional heater capacity, 50 HzHeater Capacity kW Nominal Heater Rating Ton 10 kWKW Heat No Heat Circ1 Circ2 Model Volts Phase Electrical data, 60 Hz ampsElectrical data, 50 Hz amps Troubleshooting guide Problem Probable Cause RemedyLiebert InteleCool2 Monthly FiltersFan Section Semiannually Compressor SectionParts Refrigeration system parts, 1.5 and 2 ton unitsRefrigeration system parts, 3 ton units Refrigeration system parts, 4-ton units Refrigeration system parts, 5-ton units Electric panel, 1.5- and 2-ton units 11-10Electric panel parts, 3-ton units Electric panel parts, 4-ton unit Electric panel parts, 5-ton unit Motor parts, heater, Economizer, 1.5- and 2-ton units High ambient optionMotor parts, heater, Economizer, 3-ton units Motor parts, heater, Economizer, 4-ton units Motor parts, heater, Economizer, 5-ton units Condenser/piping assembly Crankcase heater reciprocating compressor onlyEvaporator blower Evaporator coil and expansion valveElectric panels Heater assembly Economizer assembly Soft start device To compressor capacitorParts Parts Page Ne t ItiTi n That

2 specifications

Emerson 2 is an advanced automation and control technologies platform designed to enhance operational efficiencies across various industries. This next-generation system builds upon its predecessor, incorporating cutting-edge technologies that facilitate seamless integration and data-driven decision-making.

One of the main features of Emerson 2 is its robust IIoT (Industrial Internet of Things) capabilities. These features allow for real-time data collection and monitoring, which empower users to gain insights into their processes. By leveraging smart sensors and devices, Emerson 2 ensures that vital information is captured and communicated effectively, leading to improved process optimization and reduced downtime.

Emerson 2 also offers enhanced analytics tools, enabling organizations to analyze large volumes of data efficiently. Users can utilize advanced algorithms and machine learning models to identify patterns, predict equipment failures, and optimize maintenance schedules. This predictive maintenance capability is critical for minimizing operational disruptions and maximizing asset life.

The platform is designed with user experience in mind, featuring an intuitive interface that simplifies navigation and enhances usability. Operators can easily access real-time dashboards and visualizations, allowing them to make informed decisions rapidly. Customizable reporting tools further enhance user interaction, enabling teams to generate reports that meet their specific operational needs.

Security is a top priority for Emerson 2, which incorporates advanced cybersecurity measures to protect sensitive data. With built-in encryption protocols and secure communication standards, Emerson 2 ensures that information is safeguarded against potential threats and cyberattacks.

Another noteworthy characteristic of Emerson 2 is its scalability. The platform is designed to grow with businesses, allowing for the integration of additional sensors, devices, and modules as operational demands evolve. This flexibility means that companies can adapt their automation strategies without overhauling their entire system.

Finally, Emerson 2 supports various industry standards and protocols, facilitating interoperability with existing systems and equipment. This feature enables a smoother transition for businesses looking to upgrade their automation capabilities without extensive overhauls.

In summary, Emerson 2 represents a significant leap in automation technology, featuring IIoT integration, advanced analytics, user-friendly interfaces, robust security, scalability, and interoperability. As industries seek smarter and more efficient solutions, Emerson 2 stands out as a versatile platform equipped to meet the challenges of modern manufacturing and process control.