Emerson Process Management TF396 Ordering Information, Accessories First Time Installation Guide

Page 6

MODEL TF396

SECTION 1.0

 

DESCRIPTIONS AND SPECIFICATIONS

1.3 ORDERING INFORMATION

The Model TF396 TUpHFET Non-glass ISFET pH Sensor is housed in a molded reinforced polypropylene body with 1 in. MNPT threads suitable for insertion, submersion or flow through installation, or housed in a 316SST body for use with a 2.0 inch Tri-Clamp fitting. The sensor includes an ion-selective field effect transistor, a patented reference junction, a solution ground, and a recessed protective tip. The Model TF396 includes automatic temperature compensation (Pt 100 RTD) and connector for use with a cable assembly that includes an integral cap with mating connector and a choice of 20 or 50 ft of cable.

MODEL

TF396 NON-GLASS ISFET pH SENSOR

 

CODE

PREAMPLIFIER/CABLE (Required Selection)

 

 

01

Threaded body for insertion/submersion service

 

02

316 SST Body for use with Tri-clamp (PN 23513-00, ordered separately)

 

 

 

 

 

 

 

 

CODE

CABLE AND INTEGRAL CAP WITH PREAMPLIFIER

 

C08

20 ft cable

 

 

 

C50

50 ft cable

 

 

 

 

 

 

 

TF396

-01 -C08

EXAMPLE

 

 

 

 

 

Notes:

1For first-time installation, cable and integral cap with preamplifier (Codes C20 or C50) must be included.

2For installations with distances (between the sensor and instrument) of more than 50 ft; a cable extension junction box should be used.

3The Model TF396 is compatible with Models 54e, 1055, 81, 3081, 4081, 1056, XMT and 5081 .

ACCESSORIES: FIRST TIME INSTALLATION GUIDE

CODE

MOUNTING ASSEMBLIES

915240-03

Tee, Flow-through, 2 in. PVC, 3/4 in. NPT

915240-04

Tee, Flow-through, 2 in. PVC, 1 in. NPT

915240-05

Tee, Flow-through, 2 in. PVC, 1-1/2 in. NPT

11275-01

Handrail Mounting Assembly

2002011

Flow Cell, CPVC, 1 in. FNPT

24091-00

Cell, Low Flow

SQP10098-LQD

2.0 inch Tri-Clamp adapter (SQ11109; formerly PN 23513-00)

CODE

REMOTE JUNCTION BOXES

23550-00

Cable extension junction box

 

 

CODE

EXTENSION CABLES (requires a remote junction box)

9200273

Cable, Extension, 11 Conductor, Shielded, Unprepped

23646-01

Cable, Extension, 11 Conductor, Shielded, Prepped, per ft

 

 

CODE

OTHER

2001492

Tag, Stainless Steel, Specify Marking

12707-00

Jet Spray Cleaner

23242-02

Mounting Adapter, 1-1/2 in. Insertion, 1 in. x 3/4 in.

7901631

Shroud, PVC

9210012

Buffer Solution, 4.01pH, 16 oz.

9210013

Buffer Solution, 6.86pH, 16 oz.

9210014

Buffer Solution, 9.18pH, 16 oz.

9322014

Union, KYNAR

9330022

Union, CPVC

2

Image 6
Contents Combination pH Sensor Hazardous Area Installation Essential InstructionsModel TF396 List of Figures Number TitleList of Tables Section Description and Specifications Features and ApplicationsMinimum Process Conductivity 75 µS/cm nominal 100 µS/cm Accessories First Time Installation Guide Ordering InformationMounting Section InstallationUnpacking and Inspection Flow Through and Insertion Mounting4TF39604 B 40396P05 4TF39603 Jet Spray Cleaner PN LOW Flow Cell PNSection Wiring Model TF396 41055102 40508114 Section Start UP and Calibration Instrument Configuration for USE with Model TF396Recommended two-point buffer calibration procedure Sensor PreparationElectrode Cleaning Section MaintenanceAutomatic Temperature Compensator Ro and R1 Values for Temperature Compensation ElementsSection Return of Material Warranty RepairNON-WARRANTY Repair GeneralReturn of Materials Request Sensor or Circuit Board onlyWarranty Return of MaterialSpecifications subject to change without notice