Emerson 396VP, 398VP, 397 instruction manual Part Number Description

Page 12

MODEL 396/396VP/397/398/398VP

SECTION 1.0

 

DESCRIPTION AND SPECIFICATIONS

ADDITIONAL ACCESSORIES FOR MODEL 396, 396VP, 398 AND 398VP TUpH SENSORS

PART NUMBER

DESCRIPTION

 

 

33046-00

Ferrule 1 in., split 316 SS

 

 

33211-00

Adapter retrofit for PN 915240-04

 

 

9550167

EPDM O-ring for process connector (PN 23166-00)

 

 

9310100

Ferrule, 1 in. Teflon1

9310096

Nut, Swage, 1 in. stainless steel

 

 

9550167

O-ring, 2-214 EPDM

 

 

1 Teflon is a registered trademark of E.I. du Pont de Nemours & Co.

ADDITIONAL ACCESSORIES FOR MODEL 397 TUpH SENSOR AND THE QUIK-LOC KIT

PART NUMBER

DESCRIPTION

 

 

23753-00

PEEK replacement adapter for Quik-Loc kit (PN 23757-01)

 

 

23753-01

PEEK replacement adapter for Quik-Loc kit (PN 23757-00)

 

 

9160441

1 in. MNPT 316 stainless steel coupler

 

 

9160442

1 in. Plug, stainless steel

 

 

9160447

1 in. EP Gasket for coupler

 

 

2002011

1-1/2 in. CPVC Tee with 1 in. FNPT Connection

 

 

ADDITIONAL ACCESSORIES USED FOR MODELS 396, 396VP, 397, 398, AND 398VP TUpH SENSORS

PART NUMBER

DESCRIPTION

 

 

22698-00

Preamplifier plug-in for J-box, 1003 compatible

 

 

22698-02

Preamplifier plug-in for J-box, 1181/1050 compatible

 

 

22698-03

Preamplifier plug-in for J-box, 1054A/B, 2054,2081 compatible

 

 

22743-01

Pt 100 preamplifier, 1181 compatible

 

 

22744-01

3K Preamplifier, 1181 compatible

 

 

23054-03

Remote J-box with preamplifier for Solu Cube Model 2700

 

 

23309-03

Remote Junction box, for preamplifier Model 1181

 

 

23309-04

Remote Junction box, for preamplifier Model 1054 Series, 2054, 2081

 

 

23555-00

Remote Junction box, with preamplifier, 54/e, 81, 3081, 4081 compatible

 

 

23557-00

Preamplifier for Junction box for Models 54/e, 1055, 81, 3081, 4081

 

 

23646-01

Extension cable 11 conductor, shielded, prepped

 

 

9200273

Extension cable11 conductor, shielded, unprepped

 

 

9210012

Buffer solution, 4.01 pH, 16 oz.

 

 

9210013

Buffer solution, 6.86 pH, 16 oz.

 

 

9210014

Buffer solution, 9.18 pH, 16 oz.

 

 

2001492

Stainless Steel Tag, Specify Marking

 

 

9200254

Cable, 4 cond., 22 AWG, 2 shielded pair

 

 

8

Image 12
Contents PH/ORP Sensors ModelHazardous Area Installation Essential InstructionsTable of Contents List of TablesWiring Models 396-54-62, 397-02-54-62, & 398-54-62 to Model List of FiguresSection Description and Specifications TUpH Features and ApplicationsSection Performance & Physical Specifications Model QUIK-LOC KITOrdering Information Model398 10 32 Model Mounting Accessories optional Part Number Description Section Installation Safety Warning2 inch Pipe Tee PN 2002011 with 1 inch threaded connections Dimensional Drawing For Models 396 Section 40039603 C Dimensional Drawings For Model 397 in the Quik-Loc Unit Electrical Installation 40039610 40038920 40039607 40039606 40039608 D 40039605 40039611 Section 21. Wiring Model 396VP and 398VP to 24. Wiring Model 396VP and 398VP to Model 28. Wiring Model 396VP and 398VP to 33. Wiring Model 396VP/398VP to Models 54/54e 36. Wiring Model 396VP-54 to Model 38. Wiring Models 396VP & 398VP to Model Xmt-P-HT-10 39. Wiring Models 396/397/398 to Model 5081-P Calibration Using Buffer Solutions or Grab Samples Section Start UP and CalibrationSensor Preparation Section Maintenance Sensor is in Pressurized SystemSection Troubleshooting Troubleshooting Probable Cause RemedyWarranty Repair NON-WARRANTY RepairSection Return of Material GeneralWarranty Specifications subject to change without notice
Related manuals
Manual 40 pages 53.23 Kb

398, 397, 396VP, 398VP, 396 specifications

Emerson offers a wide range of advanced process control instruments, and among them, the Emerson 396, 398VP, 396VP, 397, and 398 stand out for their precision, reliability, and versatility. These models are designed to cater to the demanding needs of industrial applications, particularly in the areas of pressure, temperature, and flow measurement.

The Emerson 396 series focuses on providing robust pressure and temperature measurement solutions. One of its standout features is its digital manometer functionality, which allows for precise measurement of differential pressure. This makes it an excellent choice for HVAC applications and other industrial processes where accuracy is critical. The 396 model is equipped with advanced signal processing capabilities, allowing for the adjustment of sensitivities and ranges according to specific application needs.

Moving on to the 398VP and 396VP models, these variants incorporate advanced validation features that ensure data integrity and accuracy. They are designed with user-friendly interfaces that not only simplify operation but also enhance user experience. The 398VP model, in particular, is celebrated for its versatility, as it can operate in both electrical and pneumatic environments. Additionally, the model comes with integrated diagnostics, which simplifies maintenance by providing real-time data on operational status.

The Emerson 397 model focuses on flow measurement and control. It integrates technologies that minimize the impact of environmental factors on measurement accuracy. Its intelligent algorithms provide compensation for temperature and pressure fluctuations, ensuring consistent performance in varying conditions. This model is also compatible with various fieldbus protocols, facilitating easy integration into existing systems.

Finally, the Emerson 398 model is known for its high-performance digital operation. It includes features such as remote monitoring and control capabilities, which allow operators to manage processes from any location. The 398 is specifically designed to meet the rigorous requirements of industries like oil and gas, chemical, and power generation.

In summary, the Emerson 396, 398VP, 396VP, 397, and 398 models are equipped with cutting-edge technologies and features tailored for industrial efficiency, reliability, and accuracy. Their user-friendly interfaces, advanced diagnostics, and compatibility with modern communication protocols make them invaluable tools for engineers and operators in various sectors, enhancing overall productivity and performance.