RIDGID R175RNA manual Maintenance

Page 18

MAINTENANCE

WARNING:

When servicing use only identical RIDGID replacement parts. Use of any other parts may create a hazard or cause product damage.

WARNING:

Always wear safety goggles or safety glasses with side shields during power tool operation or when blowing dust. If operation is dusty, also wear a dust mask.

WARNING:

Disconnect the tool from the air supply before performing maintenance. Failure to do so could result in serious personal injury.

GENERAL MAINTENANCE

Avoid using solvents when cleaning plastic parts. Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use. Use clean cloths to remove dirt, dust, oil, grease, etc.

WARNING:

Do not at any time let brake fluids, gasoline, petroleum-based products, penetrating oils, etc., come in contact with plastic parts. Chemicals can damage, weaken or destroy plastic which may result in serious personal injury.

LUBRICATION

�Frequent, but not excessive, lubrication is required for best performance. Oil for pneumatic fastening tools added through the air line connection will lubricate the internal parts.

Do not use detergent oil or additives as these lubricants will cause accelerated wear to the seals and bumpers in the tool, resulting in poor tool performance and frequent tool maintenance.

COLD WEATHER OPERATION

For cold weather operation, near and below freezing, the moisture in the air line may freeze and prevent tool operation. We recommend the use of air tool lubricant or permanent antifreeze (ethylene glycol) as a cold weather lubricant.

CAUTION:

Do not store tools in a cold weather environment to prevent frost or ice formation on the tools’ operating valves and mechanisms that could cause tool failure.

NOTE: Some commercial air line drying liquids are harmful to “O” rings and seals. Do not use these low temperature air dryers without checking compatibility.

AIRSUPPLY-PRESSURE AND VOLUME

Air volume is as important as air pressure. The air volume supplied to the tool may be inadequate because of under- size fittings and hoses, or from the effects of dirt and water in the system. Restricted air flow will prevent the tool from receiving an adequate volume of air, even though the pres- sure reading is high. The results will be a slow operation, misfeeds or reduced driving power. Before evaluating tool problems for these symptoms, trace the air supply from the tool to the supply source for restrictive connectors, low points containing water and anything else that would prevent full volume flow of air to the tool.

REPLACING THE NOSEPIECE

The nosepiece with carbide inserts may be replaced when the inserts are worn.

nDisconnect the tool from the air supply.

nLoosen the nose screws with the hex key provided.

nRemove the screws.

nRemove the old nosepiece.

nInstall the new nosepiece. Align the holes in the nosepiece with the holes in the nose of the tool.

nReplace the nose screws and tighten with the hex key. Do not overtighten.

NOSE OF TOOL

NOSEPIECE

SCREWS

18

Image 18 Contents
OPERATOR’S Manual R175RNATable of Contents IntroductionService General Safety RulesPersonal Safety Work AreaSpecific Safety Rules OperationAIR Supply and Connections Loading ToolSymbols Symbol Name DESIGNATION/EXPLANATIONGlossary of Terms Activate operating controlsFeatures Product SpecificationsQUICK-CONNECT Swivel Connector Adjustable ExhaustDepth of Drive Adjustment Know Your Coil Roofing NailerUnpacking AssemblyOperation Packing ListAdjusting the Exhaust Preparing the Tool for USEConnecting the Tool to AN AIR Supply Adjusting the Offset Magazine See Figures 5Loading the Tool with Nails See Figures 7 Contact Actuation Mode Using the Selectable Trigger Single Sequential Actuation Mode See Figures 10Setting the AIR Pressure Drive Depth AdjustmentUsing the Shingle Guide Removing NailsClearing a Jammed Fastener Maintenance Accessories TroubleshootingProblem Possible Cause Solution Page Warranty Customer Service Information