Emerson CF712TZ01, CF712WW01, CF712BS01 Trouble Shooting, Trouble Probable Cause Suggested Remedy

Page 10

!WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.

Trouble Shooting

TROUBLE

 

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

 

1. Fan will not start.

1.

Fuse or circuit breaker blown.

1.

Check main and branch circuit fuses or circuit breakers.

 

 

 

!

WARNING: Make sure main power is turned off.

 

2.

Loose power line connections to the fan, or loose

2.

Check line wire connections to fan and switch wire

 

 

switch wire connections in the switch housing.

 

connections in the switch housing.

 

3.

Reversing switch in neutral position.

3.

Make sure reversing switch position is all the way to one

 

 

 

 

side.

 

 

 

 

 

2. Fan sounds noisy.

1.

Blades not attached to fan.

1.

Attach blades to fan before operating.

 

2.

Screws securing fan blade flanges to motor hub

2.

Check to make sure the screws which attach the fan

 

 

are loose.

 

flanges to the motor hub are tight.

 

 

 

!

WARNING: Make sure main power is turned off.

 

3.

Wire connectors inside switch housing rattling.

3.

Check to make sure wire connectors in switch housing

 

 

 

 

are not rattling against each other or against the interior

 

 

 

 

wall of the switch housing.

 

4.

Motor noise caused by solid-state variable

4.

Some fan motors are sensitive to signals from Solid-

 

 

speed control.

 

State variable speed controls. If Solid-State Control

 

 

 

 

is used and motor noise results choose an alternative

 

 

 

 

control method.

 

5.

Screws holding blades to flanges are loose.

5.

Tighten screws securely.

 

 

 

 

 

3. Fan wobbles

1.

Setscrews in motor coupling are loose.

1.

Tighten both setscrews securely in the motor coupling.

excessively.

2.

Setscrew in hanger ball/downrod assembly is

2.

Tighten the setscrew in the hanger ball/downrod

 

 

loose.

 

assembly.

 

3.

Screws securing fan blade flanges to motor are

3.

Check to be sure screws which attach the fan blade

 

 

loose.

 

flanges to the motor are tight.

 

4.

Fan blade flanges not seated properly.

4.

Check to be sure the fan blade flanges seat firmly and

 

 

 

 

uniformly to the surface of the motor.

 

5.

Hanger bracket and/or ceiling outlet box is not

5.

Tighten the hanger bracket screws to the outlet box,

 

 

securely fastened.

 

and/or secure outlet box.

 

6.

Fan blades out of balance.

6.

Interchanging an adjacent (side-by-side) blade pair can

 

 

 

 

redistribute the weight and result in smoother operation.

 

 

 

 

 

10

U.L. Model No.: CF712

Image 10
Contents Read and Save These Instructions Safety Instructions Additional Safety Instructions for InstallationTools Needed for Assembly MaterialsRemoval Hanger Bracket Installing The Hanger Ball/Downrod AssemblyFor Standard Mounting Installing Hanger Bracket Installing The Ceiling Cover On The Fan Motor HousingFor Close-to-the-Ceiling Mounting Hanging The Ceiling Fan Wiring The Ceiling FanStandard Method Using Hanger Ball/Downrod Electrical RequirementsInstalling The Fan Blades Installing Ceiling CoverInstalling The Light Fitter Glass Bowl cap FigureMaintenance Using Your Ceiling FanAccessories Trouble Shooting Trouble Probable Cause Suggested RemedyLimited Warranty Repair Parts Listing
Related manuals
Manual 12 pages 18.21 Kb

CF712SCB01, CF712TZ01, CF712WW01, CF712ORB01, CF712AW01 specifications

The Emerson CF712AB01, CF712WB01, CF712BS01, CF712AW01, and CF712ORB01 are a series of stylish ceiling fans designed to enhance the aesthetic and comfort of any living space. Each model is equipped with key features and modern technologies that set them apart in the market.

One of the standout features of the Emerson CF712 series is its sleek design that effortlessly blends into various interior styles. Whether it's the Antique Brass finish of the CF712AB01, the White finish of the CF712WB01, the Brushed Steel of the CF712BS01, the Aged Walnut of the CF712AW01, or the Oil-Rubbed Bronze of the CF712ORB01, each fan adds a touch of elegance to any room. The color options cater to different design preferences, allowing homeowners to find the perfect match for their decor.

In addition to their aesthetic appeal, the fans in this series are designed for optimal functionality and energy efficiency. The blade pitch and motor design work together to produce a powerful airflow, ensuring that any room feels comfortable regardless of the season. The fans are fitted with reversible motors, enabling users to switch the direction of the blades with ease. This feature allows for a cooling breeze in the summer and a gentle updraft in the winter, aiding in the circulation of warm air.

Installation and maintenance of the CF712 ceiling fans are simplified through innovative engineering. Many models come with a Quick Connect system for more effortless assembly. The blades are crafted from high-quality materials that are not only durable but also easy to clean, ensuring longevity and reduced maintenance effort.

Moreover, these fans are often compatible with various control options, including pull chains and remote controls, giving users the flexibility to operate them from anywhere in the room. Some models also support smart home technology, allowing integration with platforms like Alexa and Google Assistant for voice-activated control.

The Emerson CF712 series caters to sustainability-conscious consumers as well. By consuming less electricity than traditional fans while still delivering high performance, these fans help reduce energy costs and environmental impact.

Overall, the Emerson CF712AB01, CF712WB01, CF712BS01, CF712AW01, and CF712ORB01 ceiling fans combine elegant design, advanced technology, and energy-efficient operation, making them an excellent choice for enhancing both style and comfort in any home.