Thermo Products USDT2004 manual Menmode is for use in advanced applications only. See P.9

Page 6

P ower Connections: A small blade screwdriver may be used to fasten miniaturized terminal block screws while the corresponding wire is inserted.

NOTE 1: Always disconnect the controller from power supply before opening the housing.

NOTE 2: The controller should be properly grounded. Flexible wires, 18/3 AWG (gauge/conductor) simplify connection to the terminals. The power terminal block will accommodate wire sizes to 14 AWG. All other connections should be secured and adequately tightened, as loose power connections will over-heat, and may cause fire.

NOTE 3: It is important that the specified output loads (245 Watts) are not exceeded. Where these loads expect to exceed, external relays must be used. It is good practice to install a switch to disconnect the controller and pump from power. Always keep power cables away from sensor cables and other low voltage signal cables.

NOTE 4: To protect against lightning damage, the system must be grounded according local regulation. Sensor failures due to the weather or electrostatic are mostly due to poor grounding.

Your controller displays requested information one at a time. The unit display window has three lines to inform you about the system's status, unit of displayed parameter and its value.

Upper Line Display Symbolic display of sensor location, reading unit, and operation domain Center Line Display Sensor ID and its reading in normal mode (user interface window) Lower Line Display Set-point indicator that illuminates only during programming mode

ðPush selection key once to move to the next selection; or increase the selected parameter by one unit.

ïPush selection key once to move to the previous selection; or decrease the selected parameter by one unit.

òPush selection key once to enter the advanced (Par or *Men) mode. Once in selected

mode, press one more time to select the parameter in that mode. Selected parameter blinks allowing the user to modify it. You can modify the selected parameter while the middle window blinks by pressing the ï or ð key.

ñPush selection key once to accept selection (blinking stops showing the new set-point steady) or go back to the previous selection.

*Menmode is for use in advanced applications only. See P.9.

6

Image 6
Contents Usdt Installation and User’s Guide Introduction Control unit has the following functionsInstallation Following sa fety precautions are strongly recommendedPage Page Menmode is for use in advanced applications only. See P.9 Energy collected in kWh GAL Flow rate gallon/hHysteresis Bandwidth Diff ?1Selection DesignationSEN BTUOUT LLPAlarm StartRkty Sens EnablDisab INSNo Circ OK CircMalfunction, but realistic temperature values Incorrect display of temperatures