S A F E T Y
General Safety
CAUTION: It is essential that all instructions in this manual be followed to ensure proper operation of the equipment and safety of operating person- nel. Use of equipment not specified herein, may impair protection provid- ed by equipment. The use of this symbol is used throughout manual to highlight important safety issues. Please pay particular attention to these items.
Electrical Shock Caution
Certain LV800 models are powered with HIGH VOLTAGE. No operator serviceable parts are inside. All servicing is to be performed by qualified personnel. Each
Electromagnetic Compatibility (EMC)
The LV800 was tested and found to comply with the standards listed below. The LV800 should not be used in residential or commercial envi- ronments. Compliance to EMC standards was demonstrated by means of a test setup using the following installation methods.
1)LV800 enclosure was connected to earth ground (protective earth).
2)No specific wiring convention was used to supply power or to retrieve output signal from the LV800.
EMC Emissions:
Meets EN
EN 55011 Radiated and conducted emissions
(Class A- industrial) EN
Meets FCC Part 15B: RF Devices, Unintentional Radiators
CISPR 11 Radiated and conducted emissions (Class A- industrial)
EMC Immunity:
Meets EN
EMC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
| S P E C I F I C AT I O N S |
Power: | 115VAC (±15%); 2.5VA; 50/60Hz / 230VAC (±15%); 2.5VA; 50/60Hz |
Altitude: | 6562 ft (2000 m) max |
Installation Category: | II |
Pollution Degree: | 4 (Reduced to 2 by enclosure) Suitable for indoor/outdoor use |
Ambient Op Temp: | |
*Internal Bin Temp: | To +176˚ F (+80˚ C) w/alum. mount (<104˚ F (40˚ C) ambient) |
Output Relay: | To +400˚ F (+204˚ C) w/SS mount (<122˚ F (50˚ C) ambient) |
SPDT, 5A @ 250VAC, 30VDC maximum | |
External Indicators: | Red and green LEDs indicating power and operating mode |
Sensitivity: | |
Stability: | ±0.015pf per degree F (±0.027pf per degree C) @ 0.5pf setting |
Time Delay: | 0.25 to 15 sec |
| 0.25 sec |
Switch selectable - HI/LO | |
Protected via driven shield to 150 ohm load | |
Enclosure: | Cast alum |
Conduit Connection: | Two (2) 3/4” NPT connections |
**Approvals: | CSAUS CSAC Ordinary Locations, CE Mark(Ordinary location only) |
Standard/Food Grade Probe | |
Mounting: | |
Probe Material: | 3/8in(9.5mm) dia. 316SS probe & guard, PPS insulators |
Probe Length: | 16in(406mm) from alum mounting |
Temp (Probe Only): PPS+450˚ F (+232˚ C) max; | |
Pressure: | 50 psi(3.5 bar) max (alum connection);150 psi(10 bar) max (3/4” NPT SS) |
Stub Probe |
|
Mounting: | |
| 3/4” NPT 316SS and |
Probe Material: | 3/8in(9.5mm) dia. 316SS probe & guard, PPS insulators |
Probe Length: | Cut to customer specification; application dependent |
Temp (Probe Only): PPS +450˚ F (+232˚ C) max | |
Pressure: | 50 psi(3.5 bar) max (aluminum); 150 psi(10 bar) max (3/4 NPT SS) |
*Influenced by mounting, material thermal conductivity and ambient temperature.
9