Omega Engineering CL531 manual Warranty/Disclaimer

Page 9

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 37 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal three (3) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.

BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.

FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:

1.Purchase Order number under which the product was PURCHASED,

2.Model and serial number of the product under warranty, and

3.Repair instructions and/or specific problems relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:

1.Purchase Order number to cover the COST of the repair,

2.Model and serial number of the product, and

3.Repair instructions and/or specific problems relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.

OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

© Copyright 2005 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

Image 9
Contents User’s Guide Servicing North America Basic Keypad Operations Error ConditionsEZ-Dial Knob Quick Reference Bar GraphEZ-CheckSwitch Source ModeWire Transmitter Simulation Mode Read Mode Power and Measure Transmitter ModeGeneral Specifications SpecificationsCL531 Field Calibration Procedure Page WARRANTY/DISCLAIMER Shop online at omega.com

CL531 specifications

Omega Engineering is renowned for its precision instruments and innovative solutions in the field of measurement and control. Among its notable offerings is the Omega CL531, an advanced process controller that has gained recognition for its reliability and versatility in a wide range of industrial applications.

The Omega CL531 features a powerful microprocessor-based design, which allows for precise control and monitoring of various parameters such as temperature, pressure, and flow. This capability makes it ideal for use in laboratories, manufacturing processes, and environmental monitoring. The device features a dual-display that simultaneously shows the process variable and the setpoint, providing users with clear visibility of critical data.

One of the standout technologies integrated into the CL531 is its user-friendly interface. The controller is designed with a simple navigation system, allowing operators to configure settings and adjust parameters quickly. This ease of use is complemented by a comprehensive manual and support resources, ensuring that users can efficiently operate the device without extensive training.

The CL531 also boasts advanced control capabilities, including PID control, which optimizes the regulation of process variables. This functionality is crucial for maintaining stability in processes where precise control is essential. Users can easily adjust the PID settings to tailor the controller's performance to their specific application requirements.

In addition to its control features, the Omega CL531 supports a wide range of input types, including thermocouples, RTDs, and voltage or current signals. This versatility enables users to integrate the controller into existing systems without the need for significant modifications, making it a cost-effective solution for upgrading process control technologies.

Another significant characteristic of the CL531 is its robust construction, designed to withstand the demands of industrial environments. With its durable housing and reliable components, the device ensures long-term performance even in challenging conditions.

In summary, the Omega CL531 serves as a powerful and versatile tool for process control in various applications. Its advanced features, user-friendly interface, and robust design make it an essential instrument for industries requiring precision monitoring and control. Whether in laboratory settings or manufacturing lines, the Omega CL531 stands out as a top choice for engineers and technicians seeking reliable process management solutions.