EN Technical Data
Distance measurement
Typical Measuring Tolerance* ± 1.5 mm / 0.06 in ***
Maximum Measuring | ± 2.5 mm / 0.10 in *** |
Tolerance** |
|
Range of target plate | 60 m / 197 ft |
Typical Range* | 60 m / 197 ft |
Range at unfavourable | 50 m / 164 ft |
condition **** |
|
Smallest unit displayed | 0.1 mm / 1/32 in |
Ø laser point | 6 / 30 / 40 mm |
at distances | (10 / 50 / 60 m) |
General
Laser class | 2 |
Laser type | 635 nm, < 1 mW |
Protection class | IP54 (dust- and splash |
| water protected) |
Autom. laser switch off | after 90 s |
Autom. power | after 180 s |
Battery durability (2 x AAA) | up to 5000 measure- |
| ments |
Dimension (H x D x W) | 117 x 57 x 32 mm |
| 4.6 x 2.4 x 1.3 in |
Weight (with batteries) | 0.14 kg / 4.938 oz |
Temperature range: | |
- Storage | |
- Operation | |
| 14 to 122 °F |
*applies for 100 % target reflectivity (white painted wall), low background illumination, 25 ºC
**applies for 10 to 500 % target reflectivity, high back- ground illumination, - 10 ºC to + 50 ºC
***Tolerances apply from 0.05 m to 10 m with a confi- dence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.2 mm/m for distances above 30 m
****applies for 100 % target reflectivity, background illumination of approximately 30'000 lux
Functions
Distance measuring | yes |
Min/Max measuring | yes |
Permanent measuring | yes |
yes | |
Addition/Subtraction | yes |
Area | yes |
Volume | yes |
Pythagoras | |
Memory | 10 displays |
Beep | yes |
Illuminated display | yes |
Multifunctional endpiece | yes |
Message Codes
If the message Error does not disappear after switching on the device repeatedly, contact the dealer.
If the message InFo appears with a number, press the Clear button and observe the following instructions:
No. | Cause | Correction |
204 | Calculation error | Perform measurement |
|
| again. |
252 | Temperature too | Let device cool down. |
| high |
|
253 | Temperature too | Warm device up. |
| low |
|
255 | Received signal too | Change target surface |
| weak, measuring | (e.g. white paper). |
| time too long |
|
256 | Received signal too | Change target surface |
| high | (e.g. white paper). |
257 | Too much back- | Shadow target area. |
| ground light |
|
258 | Measurement | Correct range. |
| outside of meas- |
|
| uring range |
|
260Laser beam inter- Repeat measurement. rupted
Care
•Clean the device with a damp, soft cloth.
•Never immerse the device in water.
•Never use aggressive cleaning agents or solvents.
14 | Milwaukee |