Sears 204.3699969 owner manual Maintenance

Page 11

MAINTENANCE

13.If there is a blockage hero, clean it out and then reassemble the Front Inspection Plate.

If you do not find any blockage in this area, and/or the machine shuts itself off or the loss of suction persists, a more detailed inspection will be necessary as follows:

14.Unplug the machine.

15.Press in the Reset Button if the Overload Protection System has once again shut the machine down. (Figure 19)

16.Place the machine in its Upright Storage Position. (Figure 1)

17.Remove the Collection Bin.

18.Unscrew the two screws which are located in the bumper at the roar of the Lower Base Cover. (Figure 19)

19.Pivot the Lower Base Cover toward the front to disengage the 5 cover locking tabs, then lift the Lower Base Cover away,

20.Remove any accumulated dirt or threads from the brush and/or remove any large objects from this area that may have jammed the brush. Also, check that the Rotary Valve Inlet is not clogged with dirt or objects. (Figure 22)

21.Check the belt to be sure that it is in good condition. A stretched or faulty belt will prevent the machine from operating properly.

22.Replace Cover by hooking all 5 Cover lock tabs into the 5 tab slots of the base Assembly. (Figure 22)

NOTE: Height Adjustment Dial must be positioned as shown in Figure 22 to allow easy assembly of cover.

23.When all tabs are engaged, swing the Cover into place.

24.With the Cover in place, pull the top edge of the Bumper forward to check that all 5 tabs are still engaged. Refasten the screws. Do not over tighten.

If the machine still does not start, or if you still experience a loss of suction power, then take it to an authorized Sears

Service Center for repair by an Authorized Service Technician.

25.If there is little or no suction at the end of the Wand, detach the Wand from the Hose. (Figure 14, page 7) Ensure that the Hose and Wand are both clear.

9

Image 11
Contents Kenmore Destinyplus Table of Contents Read ALL Instructions Important Safety InstructionsUnit Shown with Handle Upright Storage Position Operation Connecting the HandlePower Cord USE and Storage Carrying Handle SwitchOperation Upright ReleaseAttachments to Hose Activating the Cleaning WandOn Board AI-IACHMENTS Overload Protection Keeping the Rotating Brush CleanEmptying the Collection BIN Removing a Blockage MaintenanceBlockage Alarm Maintenance Replacing a Light Bulb Replacing a Broken BeltInserting a NEW Hepa Filter Cartridge Removing a Used Hepa Filter CartridgeReplacement of Filter Housing Destinyplus Your area