DUKANE | - 4 - | Application Note |
| ||
Intelligent Assembly Solutions | AN200 | |
|
| Rev 01 |
System Input Signal Descriptions:
Isolated Operate Input - ( Pin 3 ) This system input signal receives the cycle initiation signal from automation. The minimum duration for the activation of this input is 50 mS. The maximum duration of this input is determined by the duration of the weld cycle. This input should be deactivated before the end of the weld cycle to avoid an error condition. This system input can be reconfigured to accommodate sourced (PNP) and sinking (NPN) signals as described in the SH707 configuration section of this document. Please refer to the DPC manual for details on the activation and use of the Operate (cycle initiate) feature.
Note: Reconfiguring the jumper of the SH901 jumper block on the
Isolated Press Control Input - ( Pin 5 ) This system input receives a signal from automation that activates the Dukane pneumatic press to the down position. The press will remain in the down position until this system input is deactivated. This system input can be reconfigured to accommodate sourced (PNP) and sinking (NPN) signals as described in the SH707 configuration section of this document. SH901 of the
Operate Input - ( Pin 8 ) This system input signal receives the cycle initiation signal from automation. The minimum duration for the activation of this input is 50 mS. The maximum duration of this input is determined by the duration of the weld cycle. This input should be deactivated before the end of the weld cycle to avoid an error condition. The system input can only accommodate a non- isolated sinking (NPN) signal for activation.
Note: Reconfiguring the jumper of the SH901 jumper block on the
Isolated Automation Stop/End of Weld - ( Pin 9 ) This system input receives a signal from automation that will stop the processing of portions of the welding cycle. The default functionality for this input is to end the weld portion of the DPC cycle when the system input is activated. This input can be reconfigured to Automation Stop which will stop the processing of all portions of the DPC cycle. Configuration of this feature is described in the SH704 jumper configuration section of this document.
Hand Probe Press Inhibit - ( Pin 11 ) This system input receives a signal from a Dukane hand probe that disables all press functionality.
MPC Probe / Setup Bit 1, 2, and 3 - ( Pins 12, 13, 14 ) These system inputs receive a Binary code from automation that (MPC Feature Optional) is used to select a DPC setup and a DPC probe to be used for the next welding cycle. Please
refer to the DPC manual or application AN203 for details on the activation and use of the MPC or Remote Setup Select (DPCII+ only) features.
Front Panel Control Lock - ( Pin 15 ) This system input receives a signal from automation that disables the DPC test
switch as well as the key pad for the DPC controller (DPC II+ only).
Dukane Corporation
2900 Dukane Drive Saint Charles, IL 60174 USA
Phone (630)
http://www.dukane.com/us4