1.GENERAL
1.01Dimensions inverters have been designed and manufactured for many user applications and long life. They utilize patented construction methods and high technology electronic parts and circuitry.
1.02CAUTION: Inverters produce hazardous voltages, to avoid risk of harm or fire the unit must be properly installed. There are no user serviceable parts inside, do not remove the cover. CAUTION: The inverter should not be installed in a zero clearance enclosure.
CAUTION: Damage to the inverter will occur if correct polarity is not observed when installing the DC input cables.
CAUTION: Damage to the inverter will occur if an external AC power source is applied to the inverter’s AC output or its hardwire output.
CAUTION: The inverter contains a circuit breaker and a capacitor that may produce a spark. Do not mount in a confined battery or gas compartment. CAUTION: Working in the vicinity of
sive gases during operation. There is a risk of acid exposure. There is also a risk of high current discharge from shorting the battery that can cause fire and explosion.
CAUTION: Be sure the inverter's circuit breaker or fuse are turned "OFF" during installation.
2.DESCRIPTION
2.01The inverter converts 12VDC, 24VDC or 48VDC depending on inverter model to a 120VAC, 60 HZ, having a pure sine wave form signal output.
2.02The inverter has a controlled frequency at 60 HZ + 0.6Hz.
2.03The inverter has internal protection against output short circuit, output overload and high temperature conditions.
2.04The inverter is designed to operate any 120 VAC, 60 HZ, single phase appliance, equipment or tool within its power ratings.
2.05The inverter has a ventless cover to protect the inside electronics from the elements and is designed to be used on scissor lift applica- tions.
2.06The inverter is GFCI protected but does not have standard GFCI outlets. The 120VAC, 60Hz output is supplied by a female receptacle cord attached to the unit.
2.07The inverter does not have a "On"/"Off" switch. The unit must be controlled by a remote switch, a violet wire is attached to the unit for this purpose.
|
| Inverter Ratings |
|
| ||||
Inverter |
| Input |
|
| Output___ | |||
|
|
|
|
|
|
|
| |
Model | (VDC) | (ADC) | (VAC) | (Watts) | ||||
12Z8NV | 12.6 | Up to | 80 | 120 | 800 |
| ||
24Z8NV | 25.2 | Up to | 40 | 120 | 800 |
| ||
48Z8NV | 50.4 | Up to | 20 | 120 | 800 |
|