Century IM998 Installation, Technical Specification Inverter ARC, Operating Temperature Range

Page 10

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATION INVERTER ARC™ 120

Input Voltages 60 Hz.

INPUT - SINGLE PHASE ONLY

Rated Input Current

120Vac ± 15%

20 Amps @ Rated Output

Duty Cycle

RATED OUTPUT

Output Amps

Output Volts

Input Circuit

20%

70A (Stick)

22.8 Vdc

120 Vac

OUTPUT

Output Current Range

10-90 Amps

Maximum Open Circuit Voltage

72 Volts Max.

Type of Output

DC

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

INPUT VOLTAGE /

TYPE SJT OR HARD USAGE INPUT

MAXIMUM TIME-DELAY CIRCUIT

FREQUENCY (HZ)

CORD

BREAKER OR FUSE SIZE (AMPS)

 

 

 

120/60

3 Conductor, 14 AWG

20

 

 

 

PHYSICAL DIMENSIONS

Height

Width

Length

Weight

7.5 in.

5.0 in.

10.9 in.

Approx. 14.0 lbs.

190.5 mm

127.0 mm

276.9 mm

6.4 kgs.

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-10°C to +40°C

STORAGE TEMPERATURE RANGE

-25°C to +55°C

INVERTER ARC™ 120

Image 10
Contents Inverter ARC Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a L’ArcElectromagnetic Compatibility EMC Safety Thank You Customer Assistance PolicyTable of Contents Operating Temperature Range InstallationTechnical Specification Inverter ARC Storage Temperature RangeSelect Suitable Location Safety PrecautionsInput Connections Table A.1 Output Connections120V Input Stick Welding MMAGeneral Description Safety InstructionsOperation Welding CapabilityControls and Operational Features Front Control PanelElectric ARC ARC-WELDING CircuitMaking a Weld Figure B.5 Safety Precautions MaintenanceRoutine Maintenance Troubleshooting HOW to USE Troubleshooting GuideRecommended Symptoms Course of ActionTroubleshooting Diagrams Wiring Diagram for CodePrecaucion Warnung