Century IM998 manual Operation, Safety Instructions, General Description, Welding Capability

Page 13

B-1

OPERATION

B-1

 

 

 

Read and understand this entire section before operating your machine.

SAFETY INSTRUCTIONS

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

Insulate yourself from the work and ground.

Always wear dry insulating gloves.

------------------------------------------------------------

FUMES AND GASES can be dangerous.

• Keep your head out of fumes.

• Use ventilation or exhaust to remove fumes from breathing zone.

------------------------------------------------------------

WELDING, CUTTING and

GOUGING SPARKS

can cause fire or explosion

Keep flammable material away.

Do not weld, cut or gouge on contain- ers that have held combustibles.

------------------------------------------------------------

ARC RAYS can burn.

Wear eye, ear and body protection.

------------------------------------------------------------

Only qualified personnel should operate this equip- ment. Observe all safety information throughout this manual.

------------------------------------------------------------

GENERAL DESCRIPTION

The INVERTER ARC™ 120 is a 90 amp arc welding power source which utilizes single phase input power to produce constant current output. The welding response of this Inverter has been optimized for stick (SMAW) welding.

WELDING CAPABILITY

The INVERTER ARC™ 120 is rated at 70 amps, 22.8 volts, at 20% duty cycle on a ten minute basis. It is capable of higher duty cycles at lower output currents. If the duty cycle is exceeded, a thermal protector will shut off the output until the machine cools. See Table A.1 in the INSTALLATION Section for other rated out- puts.

The INVERTER ARC™ 120 is recommended for the following Electrode Types and Diameters:

 

 

Sizes (in.)

 

 

 

 

 

 

Types

1/16

5/64

3/32

1/8

Fleetweld 37

X

X

￿

-

(E6013)

 

 

 

 

Fleetweld 35

-

-

X

￿

(E6011)

 

 

 

 

Excalibur 7018 MR

-

-

￿

-

(E7018)

 

 

 

 

 

 

 

 

 

X- 15 Amp Branch circuit or greater required.

￿- 20 Amp Branch circuit or greater required.

LIMITATIONS

The INVERTER ARC™ 120 is not recommended for pipe thawing.

INVERTER ARC™ 120

Image 13
Contents Inverter ARC California Proposition 65 Warnings SafetyElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Sûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Customer Assistance Policy Thank YouTable of Contents Technical Specification Inverter ARC InstallationOperating Temperature Range Storage Temperature RangeSelect Suitable Location Safety PrecautionsInput Connections 120V Input Output ConnectionsTable A.1 Stick Welding MMAOperation Safety InstructionsGeneral Description Welding CapabilityFront Control Panel Controls and Operational FeaturesElectric ARC ARC-WELDING CircuitMaking a Weld Figure B.5 Safety Precautions MaintenanceRoutine Maintenance HOW to USE Troubleshooting Guide TroubleshootingCourse of Action Recommended SymptomsTroubleshooting Wiring Diagram for Code DiagramsPrecaucion Warnung