Emerson CF1ORB01 MaintenanceAccessories, Trouble Shooting, Important Care Instructions

Page 9

MaintenanceAccessories

IMPORTANT CARE INSTRUCTIONS

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.

Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.

!WARNING

Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.

1.Ceiling Fan Light Kits (see store or catalog).

2.Downrod Extension Kits (see store or catalog).

3.Ceiling Fan Controls (see store or catalog).

!WARNING

The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

!WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting

TROUBLE

 

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

 

1. Fan will not start.

1.

Fuse or circuit breaker blown.

1.

Check main and branch circuit fuses or circuit

 

 

 

 

breakers.

 

 

 

!

WARNING: Make sure main power is turned off.

 

2.

Loose power line connections to the fan, or loose

2.

Check line wire connections to fan and switch

 

 

switch wire connections in the switch housing.

 

wire connections in the switch housing.

 

 

 

 

 

2. Fan sounds noisy.

1.

Blades not attached to fan.

1.

Attach blades to fan before operating.

 

2.

Loose screws in motor housing.

2.

Check to make sure all screws in motor housing

 

 

 

 

are snug (not over-tight).

 

3.

Screws securing fan blade flanges to motor hub

3.

Check to make sure the screws which attach

 

 

are loose.

 

the fan flanges to the motor hub are tight.

 

 

 

!

WARNING: Make sure main power is turned off.

 

4.

Wire connectors inside switch housing rattling.

4.

Check to make sure wire connectors in

 

 

 

 

switch housing are not rattling against each

 

 

 

 

other or against the interior wall of the switch

 

 

 

 

housing.

 

5

Screws holding blades to flanges are loose.

5.

Tighten screws securely.

 

 

 

 

 

3. Fan wobbles

1.

Setscrew in motor coupling is loose.

1.

Raise motor cover and tighten setscrew securely.

excessively.

2.

Setscrew in hanger ball/downrod assembly is

2.

Tighten the setscrew in the hanger ball/downrod

 

 

 

loose.

 

assembly.

 

3.

Screws securing fan blade flanges to motor hub

3.

Check to be sure screws which attach the fan blade

 

 

are loose.

 

flanges to the motor hub are tight.

 

4.

Fan blade flanges not seated properly.

4.

Check to be sure the fan blade flanges seat firmly and

 

 

 

 

uniformly to the surface of the motor hub. If flanges are

 

 

 

 

seated incorrectly, loosen the flange screws and

 

 

 

 

retighten according to step 13 in the section “Assembly

 

 

 

 

Instructions”.

 

5.

Hanger bracket and/or ceiling outlet box is not

5.

Tighten the hanger bracket screws to the outlet box,

 

 

securely fastened.

 

and/or secure outlet box.

 

6.

Fan blades out of balance.

6.

Interchanging an adjacent (side-by-side) blade pair can

 

 

 

 

redistribute the weight and result in smoother operation.

 

 

 

 

Or use supplied balancing kit to balance blades.

 

 

 

 

 

9

Image 9
Contents Date Code CF1AB01 CF1ORB01Materials General Information Unpacking InstructionsAssembly Instructions Position the ceiling cover trim and the ceiling cover How to Hang Your Ceiling Fan Electrical RequirementsTurn How to Wire Your Ceiling Fan Using Your Ceiling Fan THREE-SPEEDSWITCHAttaching Light Kit Trouble Shooting MaintenanceAccessoriesImportant Care Instructions For your Ceiling FanRepair Parts How to Order Repair PartsPart Number Part Description Name of Item Model Number Part Numbers Key Model No Description Repair Parts ListingWhat Will Emerson Electric Co. Do To Correct Problems What The Warranty CoversHow Can You Get Service What Is Not Covered

CF1ORB01 specifications

The Emerson CF1ORB01 is a sophisticated ceiling fan designed to blend style with functionality, making it an excellent addition to any modern home. Its sleek design and advanced technologies ensure both aesthetic appeal and efficient performance.

One of the standout features of the Emerson CF1ORB01 is its Energy Star certification. This certification indicates that the fan operates with high energy efficiency, contributing to lower electricity bills while also promoting environmental sustainability. The motor is designed to provide quiet operation, ensuring that the fan can be used in bedrooms or living spaces without causing disruptive noise.

The CF1ORB01 is equipped with a robust 153 mm x 15 mm motor that provides outstanding airflow, making it suitable for various room sizes. The fan generates a maximum airflow of around 5,400 cubic feet per minute (CFM), ensuring a comfortable and breezy environment for users. An optional remote control feature is also available, allowing for easy operation from anywhere in the room, enhancing user convenience.

Another significant characteristic is the fan's versatile blade design. The Emerson CF1ORB01 features five blades constructed from high-quality materials, ensuring durability and longevity. The blades are meticulously balanced to minimize wobbling and noise, providing a serene atmosphere while circulating air effectively. The specific finish of the blades contributes to the overall aesthetic, allowing the fan to complement a range of interior design themes.

Installation of the fan is made easier with its universal ceiling mount design, which means it can be installed on various ceiling types, whether standard or sloped. Additionally, the fan comes with a downrod that allows it to hang at the optimal height for efficiency in airflow and style.

The Emerson CF1ORB01 also features a reversible motor. This allows users to switch the fan's direction, which is especially useful for seasonal changes. In summer, the fan can create a wind-chill effect, helping to keep spaces cool. In winter, reversing the fan's direction helps circulate warm air that rises to the ceiling, promoting an even temperature throughout the room.

Overall, the Emerson CF1ORB01 stands out for its combination of elegance, efficiency, and advanced features, making it a preferred choice for consumers seeking a reliable ceiling fan.