Wall Control Installation

The fan speed control is designed to operate only one ceiling fan, and not an accessory light kit. This wall control is rated for 1.2 amps at 120 volts. To avoid erratic speeds and possible damage to your ceiling fan, use this control only with the fan pull chain switch set to its high speed setting.

NOTE: The “0” position is OFF. The four fan speeds are selected by sliding the bar to the other four speed positions (“1”, “2”, “3” and “4”).

1.Before disconnecting power, ensure that the fan is set at the highest speed.

NOTE: Electric connections should be in accordance with the National Electrical Codes and all Local Codes. Before starting, disconnect power to the circuit at the fuse box or circuit breaker panel.

2.Remove the faceplate and screws from the existing wall switch. Pull switch out from wall outlet box.

3.Disconnect wire from existing fan wall switch (Figure 14).

4.Slide the fan control in the OFF position (0).

5.Connect one BLACK wire from the fan speed control to the fan/motor lead with a wire connector (provided). (Figure 15.)

6.Connect the other BLACK wire from the fan speed control to the 120VAC hot wire with a wire connector (provided).

NOTE: Use wire connectors (supplied) to secure electrical connections.

7.Attach the fan speed control to the wall outlet box with two 6-32 x 3/4” screws (provided).

8.Position the faceplate (provided) onto the speed control. Using the two 6-32 x 1/4” screws, screw the faceplate and speed control to the wall outlet box (Figure 16).

9.Restore power at the main fuse box or circuit breaker panel.

WALL

SWITCH OUTLET

FACEPLATE

BOX

 

Figure 14

 

 

STANDARD ON-OFF

 

 

WALL LIGHT SWITCH

TO

TO FAN LIGHT

TO

NEUTRAL

TO FAN MOTOR LOAD

 

120-VOLT

 

 

LIGHT

 

 

SUPPLY

 

 

HOT

 

MOTOR LOAD

 

1.2 AMP MAXIMUM

 

BLACK

 

4

BLACK

 

3

 

2

 

 

1

 

 

0

 

 

 

 

TO 120VAC

Figure 15

 

SOURCE HOT

 

 

OUTLET BOX

FAN SPEED

CONTROL

4 3 2 1 0

6-32 x 3/4"

SCREW (2)

FACEPLATE

6-32 x 1/4" SCREW (2)

Figure 16

9

U.L. Model No.: CF901

Image 9
Contents Prima Safety Instructions Materials Unpacking InstructionsHow to Put Your Ceiling Fan Together Electrical RequirementsAs described above, or fan wobble could result PIN Hanger Ball Ceiling Cover Coupling Cover Connector How to Hang Your Ceiling Fan How to Wire Your Ceiling Fan Wall Switch Outlet Faceplate Wall Control InstallationOperation of Reverse Switch AccessoriesEnergy Efficient Use of Ceiling Fans Maintenance Trouble ShootingFor your Ceiling Fan Repair Parts Repair Parts Listing KeyDescription Model No. CF901 Limited Warranty Air Comfort Products