White Rodgers ECS750B, MCD1200W, 2SD1 Important Safety Instructions, Mounting/installation, Fire hazard

Page 4

Important Safety Instructions

Read and save these instructions

ATTENTION

Please read instructions before installing and using the air cleaner. This will help you obtain the full benefit from the air cleaner you have selected.

ARead the Owner’s Manual and Important Safety Instructions carefully. Failure to follow these instructions could cause a malfunction of the filter or unsatisfactory service.

BFollow a regular service and maintenance schedule for efficient operation.

To reduce the risk of electric shock, fire and injury to persons:

Do not use the air cleaner in wet or damp locations.

The air cleaner is not for use in cooking areas.

Do not use the air cleaner with any solid state speed control device.

Do not use the air cleaner outdoors.

Do not use the air cleaner at ambient temperatures above 95°F/35°C.

! WARNING

ELECTROCUTION HAZARD.

Disconnect mains before servicing. Failure to do so could result in serious personal injury or death.

!WARNING

Do not attempt installation of this unit unless you are familiar with the necessary tools, equipment, utility connections and potential hazards.

Installation should be performed only by a qualified service provider. Failure to do so could result in reduced performance of the unit, serious personal injury or death.

!CAUTION

CELLS MAY CONTAIN SHARP EDGES.

Use care when servicing unit or handling cells. Failure to do so could result in minor personal injury.

!WARNING

Installation of this unit must comply with local electric codes or other applicable codes.

Review and understand local codes prior to installation.

Do not use this apparatus in a flammable or explosive atmosphere. Failure to do so could result in serious personal injury or death.

Mounting/installation

Please follow the installation instructions carefully.

Disconnect power prior to installing the air cleaner.

To reduce the risk of electric shock this equipment has a grounding type plug that has a third (grounding) pin. This plug will only fit into a grounding type power outlet.

If the plug does not fit into the outlet contact qualified personnel to install the proper outlet. Do not alter the plug in any way.

Use common sense, stay vigilant and pay attention to your actions during installation. Do not install the air cleaner when tired or affected by drugs, alcohol, medicines or otherwise impaired.

Use only screws delivered in the installation kit. Using other screws may damage the air cleaner and can cause a risk of shock, fire or injury to persons.

Do not use excessive strength to fasten the screws of the mounting assembly accessories. It will damage the air cleaner or mounts causing the air cleaner to fall.

Do not remove a wall mounted air cleaner once it is installed. Take special care when cleaning a wall mounted air cleaner. Only use the special mounting kit for recessed ceiling mounted air cleaners.

Do not use the frame of the recessed ceiling to carry the weight of the air cleaner.

Fire hazard

Never use the air cleaner in areas with flammable gasses.

Never use the air cleaner to extract and/or filter flammable, smoldering or burning material.

Never use the air cleaner to extract and/or filter toxic fumes or abrasive particles.

Do not place any objects on top of the air cleaner. Do not use with a damaged cord or plug.

Do not pull the cord to remove the plug from the mains. Protect the cord against heat, oil and sharp objects. Do not run any appliance over the cord. To unplug, grasp the plug, not the cord. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not move the air cleaner without having it unplugged first.

0508082120/101203/C

Page 3

Owner’s manual

Image 4
Contents Manuel Opérateur Language Langue English USA/Canada Français CanadaTable of contents Mounting/installation Important Safety InstructionsFire hazard Maintenance MOUNTING/INSTALLATIONOperating Instructions IntroductionProgram Settings ControlTroubleshooting If leds and are flashingIf led Auto is flashing If led Standby is flashingProgram Setting 4 Manual lock Adjusting to Specific Room ConditionsTechnical Repair Guide Filter REPLACEMENT/CLEANING Reset to factory defaultPrefilter replacement Electronic filter cleaningMedia filter replacement Activated carbon or Odor Free filter replacementBasic Service Guide Condition Possible cause SolutionParts List Price €Replacement ionizing wires electronic cell Guide DE Service Technique Table des matièresInstructions DE Sécurité Importantes Manuel Opérateur Pièces DétachéesInstructions de Sécurité Importantes Montage/installationRisque d’incendie Instructions de Sécurité Importantes MONTAGE/INSTALLATION Manuel OpérateurDescription DU Produit EntretienCommande Modes DE ProgrammationReparation DES Pannes Si les diodes et clignotentSi la diode Auto clignote Si la diode Standby clignoteGuide de Service Technique Ajustement AUX Conditions Ambiantes SpécifiquesMode de Programmation 4 Barrage de l’opération manuelle REMPLACEMENT/NETTOYAGE DES FiltresRéinitialisation à la configuration d’usine Remplacement du pré-filtre Remplacement du filtre médiaNettoyage du filtre électronique Nettoyage du/des filtres électroniquesGuide DE Service Technique DE Base Panne Cause possible SolutionPièces Détachées MCS600W MCS600BRemplacement des fils d’ionisation du filtre électronique Illustrations Controlling Indoor Comfort Worldwide Since