Dimplex LI 11MER Maintenance / Cleaning, Faults / Trouble- Shooting, Decommissioning/ Disposal

Page 9

8

English

8 Maintenance / Cleaning

8.1Maintenance

To protect the paintwork, avoid leaning or putting objects on the device. External heat pump parts can be wiped with a damp cloth and domestic cleaner.

ATTENTION!

Never use cleaning agents containing sand, soda, acid or chloride as these can damage the surfaces.

To prevent faults due to sediment in the heat exchanger of the heat pump, ensure that the heat exchanger in the heating system can not be contaminated. We recommend protecting the evapo- rator by installing a bird guard in the inlet duct. At least 80% of the cross section of the grating should be open. In the event that op- erating malfunctions due to contamination still occur, the system should be cleaned as described below.

8.2Cleaning the Heating System

The ingress of oxygen into the heating water circuit may result in the formation of oxidation products (rust), particularly if steel components are used. These products enter the heating system via the valves, the circulating pumps and/or plastic pipes. It is therefore essential - in particular with respect to the piping of un- derfloor heating systems - that only diffusion-proof materials are used.

ATTENTION!

We recommend the installation of a suitable corrosion protection system to prevent the formation of deposits (e.g. rust) in the condenser of the heat pump.

Residue from lubricants and sealants may also contaminate the heating water.

In the case of severe contamination leading to a reduction in the performance of the liquifier in the heat pump, the system must be cleaned by a heating technician.

According to today's state of knowledge, we recommend using a 5 % phosphoric acid solution for cleaning purposes. However, if cleaning needs to be performed more frequently, a 5 % formic acid solution should be used.

In either case, the cleaning fluid should be at room temperature. We recommend flushing the heat exchanger in the direction op- posite to the normal flow direction.

To prevent acidic cleaning agents from entering the heating sys- tem circuit, we recommend connecting the flushing device di- rectly to the flow and return flow of the liquifier of the heat pump.

It is important that the system be thoroughly flushed using appro- priate neutralising agents to prevent any damage from being caused by cleaning agent residue remaining in the system.

Acids must be used with great care and all relevant regulations of the employers' liability insurance associations must be adhered to.

If in doubt, contact the manufacturer of the chemicals!

8.3Cleaning the Air System

Air ducts, evaporator, ventilator and condensate outflow should be cleaned of contamination (leaves, twigs, etc.) before the heat- ing period. Do this by opening the front of the heat pump. The bottom should be opened first followed by the top.

ATTENTION!

Before opening the device, ensure that all circuits are isolated from the power supply.

Remove and rehang the side panel assemblies as described in Chapter 4.

To prevent the evaporator and the condensate tray from being damaged, do not use hard or sharp objects for cleaning.

9 Faults / Trouble- Shooting

This heat pump is a quality product and is designed for trouble- free and maintenance-free operation. In the event that a fault should occur, it will be shown on the heat pump manager display. Simply consult the Faults and Trouble-shooting page in the oper- ating instructions of the heat pump manager. If you cannot cor- rect the fault yourself, please contact your after-sales service technician.

ATTENTION!

Any work on the heat pump may only be performed by authorised and qualified after-sales service technicians.

10 Decommissioning/ Disposal

Before removing the heat pump, disconnect it from the power source and close all valves. Observe all environmentally-relevant requirements regarding the recovery, recycling and disposal of materials and components in accordance with all applicable standards. Particular attention should be paid to the proper dis- posal of refrigerants and refrigeration oils.

E-8

Image 9
Contents LI 11MER Table of contents Important Information Please Read ImmediatelyLegal Regulations Directives Energy-Efficient Use Heat PumpScope of Delivery Purpose of the Heat PumpApplication Operating PrincipleTransport Switch BoxSet-UP InstallationElectrical Connection Heating System ConnectionProcedure Start-UPPreparation Maintenance / Cleaning Faults / Trouble- ShootingDecommissioning/ Disposal Performance data Device InformationIII Anhang / Appendix / AnnexesSchéma coté Maßbild / Dimension DrawingHeizbetrieb / Heating Operation / Mode chauffage Diagramme / Diagrams / DiagrammesDVVHUGXUFKVDW DWHUIORZUDWH Kühlbetrieb / Cooling Operation / Mode refroidissementStromlaufpläne / Circuit Diagrams / Schémas électriques Anhang · Appendix · Annexes Last / Load / Charge Viii HXFKWH +XPLGLW\ +XPLGLWp Abkürzungen Abbreviations Abréviations Darstellung / Schematic View / Représentation XII Xiii

LI 11MER specifications

The Dimplex LI 11MER is an innovative electric heater designed to provide efficient heating solutions for various indoor spaces. Known for its sleek design and advanced features, the Dimplex LI 11MER is an excellent choice for homeowners and businesses seeking reliability and performance.

One of the main features of the Dimplex LI 11MER is its compact size, making it ideal for small rooms or spaces where traditional heating solutions may be impractical. The slim profile allows it to be installed in tight areas without sacrificing performance. Despite its compact design, the heater delivers an impressive output of 1000 watts, providing sufficient warmth to comfortably heat spaces up to 19 square meters.

The Dimplex LI 11MER employs advanced convection heating technology, which ensures rapid heating and consistent warmth. This technology allows for the unit to heat the air quickly, circulating warm air throughout the room efficiently. As the air rises, it draws cooler air from the bottom, creating a natural convection current that helps maintain a comfortable and even temperature.

Another noteworthy feature is the electronic thermostat, which provides precise temperature control. Users can set their desired temperature, and the thermostat will automatically adjust the heater's output to maintain that temperature. This feature not only enhances comfort but also promotes energy efficiency, as the heater operates only when needed.

Safety is a top priority with the Dimplex LI 11MER. The unit is equipped with a thermal cut-out feature that prevents overheating, ensuring the heater operates safely in any environment. Additionally, the heater is designed with a robust housing that is resistant to damage and wear, providing longevity and reliability in use.

The Dimplex LI 11MER also features a modern, aesthetic design that complements various interior styles, making it a stylish addition to any room. Its quiet operation ensures that it does not disrupt the tranquility of your home or workspace, allowing for undisturbed relaxation or productivity.

Overall, the Dimplex LI 11MER stands out with its combination of compact size, advanced heating technology, precise temperature control, and safety features, making it a top choice for efficient electric heating solutions. Whether for residential or commercial use, this heater is designed to deliver comfort, reliability, and style in one convenient package.