Gianni Industries DG-600 user manual Operation Instruction

Page 5

V.Operation Instruction

WARNING: Please read all of operation instruction before proceeding.

„Enter Program Mode

Enter twice the master code : (Default setting is "12345") Yellow LED will light up you are now in the “Programming Mode”.

„Exiting from the Program Mode

Press #to exit from the programming mode, or if no activation has happened for 25 seconds , the system will return to the user mode.

„System Setting Access Mode

Enter the Programming Mode, Press 「* 0+ ??

A.Proximity Only: For Using Card/Tag Only.

??= 00, setting complete.

B.Proximity or PIN Code to open the door:

??= 01, setting complete.

C.Proximity + PIN to open the door: Card followed by PIN code to enter.

??= 02, the setting is complete.

Note 1: After using the proximity card the yellow LED blinks and input the PIN codes. If wrong PIN code is input it will automatically return to the “User Mode”.

Note 2: 5 continuous wrong pin codes will automatically deletes the card.

„Adding and deleting cards

Enter the Programming Mode, Press the card storage slot code000~599

A.Green light comes on: This slot code may register the card

I.Show card to readerÆYellow light blinks Æ input 5 digits PIN codes Æ Green light offÆ enrolled completed Ærepeat

II.Show card to readerÆ (4 audible beep) another card has already been input (duplicate card).

B. Red light comes on: This slot already has a code registered

I. Press 「**」 (deletion) Æ Green light comes on Æ Show card to reader Æ same as step “A-1”

II. Enter another slot card position.

Note 1: Regardless of system setting access mode select, you must enter a 5-digit PIN codes after showing the card to complete the register program, otherwise the card input will not be successful.

Note 2: The master code are not be used for PIN code.

„Relocking timer setting

Enter the Programming Mode, Press 「*1+??

A.Pulse mode:?? = 01~99 seconds, 05 represents 5 seconds (An audible beep) indicates setting successfullyto exit from the programming mode, or program other operating.

B.Latching mode:?? = 00 (An audible beep) indicates setting successfullyto exit from the programming mode, or program other operating.

Note: Enter00Sets the relay to latching mode. (Correct code or card entered opens the relay, and the relay stays open until the correct code or card is entered again).

Copyright Gianni Industries, Inc. All Rights Reserved.

 

P-MU-DG600 Ver. B Publish:2004.08.27

Page: 5/ 6

Image 5
Contents DG-600 Standalone Proximity Reader Product CharacteristicII. Specifications Terminal connections III. The indicator signal chartIV. Wiring diagram Operation Instruction Example 1 Door Held Open Alarm „ Alarm FunctionExample 2 Door Forced Alarm same example Example 3 Panel Tamper Alarm

DG-600 specifications

Gianni Industries has established itself as a leading name in the domain of advanced industrial solutions, and the DG-600 is one of its standout products. This device is a testament to the company’s commitment to innovation, efficiency, and user-centric design. The DG-600 is lauded for its versatility and functionality, making it an ideal choice for various industries.

At the heart of the DG-600 is its powerful processing engine. This engine is capable of handling complex tasks with ease, ensuring that users can operate it efficiently without facing slowdowns, even when running multiple applications simultaneously. This robustness is particularly beneficial in high-demand environments, where time and accuracy are of the essence.

One of the main features of the DG-600 is its intuitive interface. This user-friendly design minimizes the learning curve for new users, enabling them to exploit the device's capabilities fully. Integrated touch controls allow for seamless navigation, ensuring that operators can quickly adjust settings and access features as needed. This attention to ergonomic design is a significant aspect of the DG-600, making it not only functional but also comfortable to use.

The DG-600 also encompasses advanced connectivity options. With built-in Internet of Things (IoT) capabilities, the device can be integrated into larger industrial systems. This connectivity allows for real-time data sharing and monitoring, enhancing operational efficiency and enabling proactive maintenance. Users can expect to benefit from improved communication between devices, reducing downtime and maximizing productivity.

In terms of technology, the DG-600 utilizes cutting-edge sensor technology, which ensures precise measurements and data accuracy. This technology is crucial in sectors where precise data collection is fundamental. Furthermore, it comes equipped with robust safety features to protect both the device and its operators, aligning with industry standards and regulations.

Also noteworthy is the DG-600’s sustainability focus. Designed with eco-friendly materials and energy-efficient mechanisms, this device not only meets operational demands but also contributes to sustainability goals. This commitment to environmentally responsible manufacturing practices is an essential characteristic of Gianni Industries.

In conclusion, the Gianni Industries DG-600 combines powerful performance, intuitive design, robust connectivity, and advanced technology to meet the diverse needs of modern industries. Its emphasis on user experience and sustainability makes it a compelling choice for businesses looking to enhance their operational capabilities while remaining conscious of their environmental impact.