Dimplex S1 7KS operating instructions Evs

Page 20

APPENDIX: 12.4 WIRING DIAGRAMS

12.4.4 Legend .. 7KS to .. 14KS

A1

Wire jumper, must be inserted if no utility company disable contactor is required

A2

Wire jumper, must be removed if 2nd disable input is used

 

B3*

Thermostat, hot water

 

B4*

Thermostat, swimming pool water

 

E9*

Electric immersion heater, hot water

 

E10*

Back-up heater (boiler or electric heating element)

 

F2

Load fuse for N1 relay outputs across J12 and J13

4,0 ATr

F3

Load fuse for N1 relay outputs across J15 to J18

4,0 ATr

F4

Pressostat, high pressure

 

F5

Pressostat, low pressure

 

H5*

Lamp, remote fault indicator

 

J1...J18

Terminal connectors at N1

 

K1

Contactor, compressor

 

K11*

Electron. relay for remote fault indicator (on relay module)

 

K12*

Electron. relay for swimming pool water circulating pump (on relay module)

K20*

Contactor, back-up heater

 

K21*

Contactor, electr. immersion heater, hot water

 

K22*

Utility company disable contactor

 

K23*

SPR auxiliary relay

 

M1

Compressor

 

M11

Primary circulating pump (brine)

 

M13

Heating circulating pump

 

M15*

Heating circulating pump, heating circuit 2

 

M16*

Suppl. circulating pump

 

M18*

Hot water circulating pump

 

M19*

Swimming pool water circulating pump

 

M21*

Mixer, primary circuit

 

M22*

Mixer, heating circuit 2

 

N1

Heat pump controller

 

N7

Soft starter

 

N10*

Remote control station

 

N11*

Relay module

 

R1

External sensor

 

R2

Return sensor

 

R3

Hot water sensor (as an alternative to the hot water thermostat)

R5

Sensor for heating circuit 2

 

R6

Freeze protection sensor

 

R7

Coding resistor 8.2 kOhm

 

T1

Safety isolating transformer 230/24 VAC-28VA

 

X1

Terminal strip, mains-load 3L/PE-400 VAC-50 Hz/

 

 

Mains-control L/N/PE-230 VAC-50Hz / fuses/N- and PE-terminal block

X2

Terminal strip 24 VAC-terminal block

 

X3

Terminal strip GND terminal block for analog inputs at J2 and J6

Abbreviations:

 

EVS

Utility company disable input

 

SPR

Supplementary disable input, configurable

 

MA*

Mixer OPEN

 

MZ

Mixer CLOSED

 

*Components to be supplied by the customer

20

Image 20
Contents Operating Instructions Purpose of the Heat Pump Read Immediately Important InformationLegal Provisions and Directives Energy-Efficient Use of the Heat PumpPurpose of the Heat Pump Baseline UnitApplication Principle of OperationAccessories TransportBrine Manifold Brine PressostatInstallation MountingSound Emissions GeneralConnection on Heat Source Side Electrical ConnectionCommissioning Procedure Cleaning of Heating SideCommissioning Preparatory StepsMalfunctions Troubleshooting Cleaning of Heat Source Side11DECOMMISSIONING Shutdown in SummerAppendix Dimensioned Drawing Equipment Data Equipment Data for Brine-to-Water Heat Pumps for HeatingCharacteristics . KS M³/h Brine flow rateConditions 75 m³/h M³/h Brine flow rate Brine inlet temperature in C Heating water flow rate Control . KS to . KS Load . KS to . KS Terminal Diagram . KS to . KS MainsEVS Hydraulic Block Diagram Declaration of Conformity EC Declaration of Conformity