2. Luminaire design

2.1.International Electrotechnical Commission (IEC) Recommendations

The general recommendations for luminaire design by IEC are also applicable to T5 luminaires. Lamp-related data can be found in IEC Standards 61195 for safety and 60081 for performance.

2.2.Operating temperatures T5 VHO and HO Extreme Temperature lamps

2.2.1. Lamp temperatures

The data on the T5 lamps are based on free burning conditions in a reference circuitry and the lamp should also be tested in that way, unless stated otherwise.

2.2.2. Maximum temperatures of lamp parts

Luminaires for T5 lamps must satisfy the general requirements for luminaires as specified by IEC 60598 and, if applicable, comply with the requirements of local standards.The maximum allowed temperature of the lamp cap is 248°F, as given in IEC 61195— Double capped fluorescent lamps—Safety specifications.

2.2.3. Measuring the lamp cap for optimum lamp conditions

In comparison with cold spot mercury lamps, the relation between light output and cap temperature is less direct with amalgam lamps. Over a broad temperature range the light output is at a very high level.

2.3.General recommendations for handling and measuring T5 lamps and luminaires

2.3.1. Handling

Handling of T5 VHO and HO Extreme Temperature lamps is less critical than the handling of T5 HE/HO lamps with cold-spot technology. It is recommended to handle the lamps in a vertical position with the stamp at the lowest side.

Allow the T5 Extreme Temperature VHO and HO lamps to cool down for 10 minutes before handling.

4 OEM Design Guide Philips T5 VHO and HO Extreme Temperature Lamps and Ballasts

Image 4
Contents OEM Design Guide Content Luminaire designIntroduction Optimum operation of T5 lamps with amalgam technologyLamp temperatures Maximum temperatures of lamp partsLuminaire design Measuring the lamp cap for optimum lamp conditionsThermal luminaire design and ballast lifetime Measuring luminaires for T5 lampsThermal hints and tips Luminaire design and EMI performance Lamp holder / cap T5 VHO and HO Extreme Temperature lamp specifications Mechanical characteristicsT5 VHO and HO Extreme Temperature publication values Product offeringsLumen maintenance Lumen output curvesFirst start-up Ballast ordering, electrical and technical dataDescription of the ballast Technical data for installation Switching cycle effectsMains operation DC voltage operation during emergency back-upWiring diagrams Ballast YellowBallast Division of Philips Electronics North America Corporation