Lumen output |
|
| |||||||
| 105 |
|
|
|
|
|
|
|
|
| 100 |
|
|
|
|
|
|
|
|
(%) | 95 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Output | 90 |
|
|
|
|
|
|
|
|
85 |
|
|
|
|
|
|
|
| |
Light | 80 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Relative | 75 |
|
|
|
|
|
|
|
|
70 |
|
|
|
|
|
|
|
| |
| 65 |
|
|
|
|
|
|
|
|
| 60 |
|
|
|
|
|
|
|
|
| 0˚C | 10˚C | 20˚C | 30˚C | 40˚C | 50˚C | 60˚C | 70˚C | 80˚C |
| 32˚F | 50˚F | 68˚F | 86˚F | 104˚F | 122˚F | 140˚F | 158˚F | 176˚F |
|
|
|
| Ambient Temperature ˚C |
|
|
| ||
|
|
|
|
| (˚F) |
|
|
|
|
|
| Standard F54 T5 HO Lamps |
|
|
|
|
| ||
|
| T5 Extreme Temperature Lamps |
|
|
|
|
Figure 3.1. Relative light output of a T5 Extreme Temperature lamp in relation to the lamp ambient temperature
Figure 3.2.Typical run-up curve of a T5
Extreme Temperature lamp
Lumen maintenance — T5 Extreme Temperature
| 100% |
| 98% |
| 96% |
(%) | 94% |
| |
OutputLight | 92% |
90%
88%
0 | 5,000 | 10,000 | 15,000 | 20,000 | 25,000 | 30,000 | 35,000 |
Lamp Operating Hours
Figure 3.3. Lumen maintenance of T5 Extreme Temperature lamps
Lumen output curves
In figure 3.1., the relative light output of a typical T5 Extreme Temperature lamp in relation to the lamp ambient temperature is shown. The light output is more than 90% between 65°F and 170°F.
Run-up curves
In order to secure a fast
Lumen maintenance
The lumen maintenance of T5 Extreme Temperature lamps will be at 90% at 40% of rated average life. See figure 3.3.