Philips PAR38/ALTO manual Ordering Data, Electrical andTechnical Data, Physical Characteristics

Page 2

Philips MasterColor® Integrated 25W PAR38 Ceramic Metal Halide Lamps featuring ALTO® Lamp Technology

Ordering Data

Product

 

Pkg.

 

 

Number

Ordering Code

Qty.

Beam

MBCP2

14477-4

CDM-i25W/830/PAR38/10/ALTO

6

Spot (10˚)

26,000

14478-2

CDM-i25W/830/PAR38/25/ALTO

6

Flood (25˚)

5600

14479-0

CDM-i25W/830/PAR38/40/ALTO

6

Wide Flood (40˚)

2100

CDM-i25w/PAR38/ALTO

Warnings, Cautions and Operating Instructions

WARNING: These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.”This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada:SOR/DORS/80-381)

Electrical andTechnical Data

Wattage ––––––––––––––––––––––––––––––––25W

Input Voltage ––––––––––––––––––––––––120V±10%

Max.THD –––––––––––––––––––––––––––––––142%

Frequency–––––––––––––––––––––––––––––––60Hz Input Current3 ––––––––––––––––––––––––––––0.36

Warm-up to 80% Full Brightness –––––––––2 minutes RestrikeTime for Hot Lamps–––––––––– 5-7 minutes Minimum Operating Temp.–––––––––––– -20˚C (-4˚F)

Spectral Power Distribution

 

0.08

 

 

 

 

 

 

 

0.07

 

 

 

 

 

 

 

0.06

 

 

 

 

 

 

nm)

0.05

 

 

 

 

 

 

0.04

 

 

 

 

 

 

(W per

 

 

 

 

 

 

0.03

 

 

 

 

 

 

Power

0.02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.01

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

200

300

400

500

600

700

800

Wavelength (Nanometers)

Physical Characteristics

Bulb Size–––––––––––––––––––––––––––––––PAR38 Bulb Finish ––––––––––––––––––––––––––––––Clear

Base –––––––––––––––––––––––––––––––––Medium

Max. Overall Length (MOL) –––––––––5.33'' (135mm) Light Center Length (LCL) ––––––––––––––––––N/A

Arc Length –––––––––––––––––––––––––––––––N/A

Arc Tube Material ––––––––––Polycrystalline Alumina Max. Ring Temp. ––––––––––––––––––––65ºC (149ºF) Max. Cap Temp. ––––––––––––––––––––65ºC (149ºF) Max. Neck Temp. –––––––––––––––––––80˚C (176˚F) Max.Arc Tube to Base Eccentricity ––––––––––––––3º

Operating Characteristics

Approx. Initial Lumens4–––––––––––––––––––––1275

Approx. Mean Lumens4,5 –––––––––––––––––––––880

Rated Average Life, Hours.1 ––––––––––––––––15,000

Correlated Color Temp. (CCT)2 ––––––––––––3000K

CIE Chromaticity Approx.2 –––––––––––x-.440, y-.393 Color Rendering Index (CRI)––––––––––––––––––87

Efficacy (lpw)–––––––––––––––––––––––––––––––51

Beam Angle (at 50% of MBCP)––––––––––10˚/25˚/40˚

Operating Position

Universal-Open or Enclosed PAR Style Luminaires (Do not use in totally enclosed recessed luminaires.)

If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation.Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.

WARNING:The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures up to 1000°C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication.

If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF PERSONAL INJURY,

PROPERTY DAMAGE, BURNS AND FIRE.

This lamp contains an arc tube with a filling gas containing less than 41 nCi of Kr-85and is distributed by Philips Lighting Company, a division of Philips Electronics North America Corporation,Somerset, New Jersey, 08875.

CAUTION:TO REDUCETHE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED.

LAMP OPERATING INSTRUCTIONS:

1. At high lighting levels or when illuminating light-sensitive

materials the use of an extra UV filter is recommended.

2. Before lamp installation/replacement, shut power off and

1)Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.

2)Maximum Beam Candlepower.

3)CAUTION: New construction should allow for the current used by these lamps. Because of a power factor of 0.57 in the ballast of the lamp, the lamp uses .36 amps.

4)Measured at 100 hrs. life. Approximate lumen values listed are for vertical operation of the lamp.

5)Approximate lumen output at 40% of lamp rated average life.

This product utilizes ALTO® Lamp Technology. ALTO products pass the US EPA'sToxicity Characteristic Leaching Procedure (TCLP) and can be classified as non-hazardous waste. Check with state and local regulations.

Above specifications subject to change without notice.

© 2008 Philips Lighting Company. All rights reserved.

Philips Lighting Company

Printed in USA 12/08

200 Franklin Square Drive

P-5747-F

P.O. Box 6800

Somerset, NJ 08875-6800

 

www. philips.com

1-800-555-0050

allow lamp and fixture to cool to avoid electrical shock and

potential burn hazards.

3.Time should be allowed for lamps to stabilize in color when turned on for the first time.This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps.

4.Lamps may require up to 10 minutes to re-light if there is a power interruption.

5.Do not operate with an additional ballast, since a ballast is integrated in the lamp itself.

6.Do not use in totally enclosed recessed fixtures.

7.Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.

8.Lamp should not be used with dimmers.

9.Protect lamp, lamp socket and wiring against moisture, corrosive atmosphere and excessive heat. Lamp should be used in dry locations only.

These lamps may be used in open fixtures.

Hg:LAMP CONTAINS MERCURYManage inAccord with Disposal Laws See: www.lamprecycle.org or 1-800-555-0050

Philips Lighting

281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050

A Division of Philips Electronics North America Corporation

A Division of Philips Electronics Ltd.

Image 2
Contents Familiar PAR38 shape and size MasterColor technologyIntegrated electronic ballast Operating Characteristics Electrical andTechnical DataPhysical Characteristics Ordering Data