Electrical Connections
WARNING!
All electrical connections must be done by a
qualified electrician!
Failure to comply may result in loss of
property and/or serious injury!
•
A plug needs to be purchased for the bandsaw that matches the outlet you intend to use (A, Fig. 23).
Confirm power at the site is the same as the saw before making any electrical connections. Review the electrical schematic on page 26.
The on/off switch (B, Fig. 24) is thermally protected. If the saw motor is overloaded, or a momentary interruption of electrical current is sensed, the saw will shut off. Allow a few minutes for the saw to cool down and reset by pushing the off button.
Maintenance
Keep bearing guides clean and free of build up.
Do not let saw dust build up in the upper and lower wheel housings. Vacuum out frequently.
Keep the brake switch, located in the lower wheel housing, clean and free of saw dust.
Connect the bandsaw to a JET dust collection system.
Clean and grease the raising/lowering rack for the upper bearing guides if it becomes difficult to raise, or lower.
Clean, and oil the tensioning mechanism if it becomes difficult to adjust.
Vacuum out the motor fan cover.