RedMax AG2300 manual Maintenance, Inspection every 25 hours

Page 12

Maintenance

WARNING

Before cleaning, inspecting or repairing your unit, make sure that engine has stopped and is cool. Disconnect the spark plug terminal to avoid accidental engine starts.

Daily Inspection

Remove grass or dust, from the entire body.

Check that all nuts and screws are securely tightened, and no parts are missing.

Check for leakage of fuel.

Inspection every 25 hours

Remove the air cleaner element from the carburetor air intake cover and wash in warm, soapy water. Dry completely before installing.

Check and clean the spark plug. Adjust the electrode gap to .024~.028 if necessary.

Replacement plug: Champion RCJ6Y

Inspection every 100 hours

The muffler is equipped with a spark arrester to prevent red hot carbon from flying out of the exhaust outlet. In the State of California it is required by law (Section 4442 of the California Public Resources Code) to equip a spark arrester when a gas powered tool is used in any forest covered, brush covered, or grass covered unimproved land.

Check and tighten each fastener.

Dismount the engine and check the clutch system to see if oil is observed between the clutch lining and its drum. If any, wipe it off with gasoline.

12

Image 12
Contents AG2300 3898-93110Safety First Contents Safety Precautions  4 Work gear and clothing Things to check before using your power auger Things to check before starting up the engineThings to be careful about when using your power auger  8  Fuel Recommended Mixing Ratio Gasoline 32OILInstalling Drill Throttle Cable AdjustmentOperation Starting EngineAdjustment of Idling Speed Stopping EngineDrilling Maintenance Replacement plug Champion RCJ6Y Inspection every 100 hoursInspection every 25 hours Storage Before Long-term StorageSpecifications Model Name AG2300Parts List Parts List AG2300 AG2300 Drill and Accessory Group  19  Engine Group  21  Carburetor Group  23  Year Limited Warranty There are no other express warranties