Carrier 52P owner manual Operating Controls, Operating Modes See Figures

Page 10

OPERATING CONTROLS

The following controls are located on the front of the control box door, under front panel. To obtain access to operating controls, remove the unit front panel as shown on page 2. See Figure 18.

FAN CYCLE SWITCH — (Typically available at wall thermostat on RC or RP units.) This allows the fan to operate in two modes:

CON (Continuous) — This setting allows the fan to run continuously, circulating air even when the tem- perature setting has been satisfied. This switch helps to maintain the room temperature closer to the ther- mostat setting. Use this switch position when maxi- mum comfort is desired. This is the factory default setting.

CYC (Cycle) — This setting allows the fan to cycle on and off with the compressor during heating or cooling. The fan stops when the temperature setting is satis- fied. This results in longer unit off-time and wider variations in room temperature and humidity.

OUTDOOR THERMOSTAT (52CQ and 52PQ HEAT PUMP UNITS ONLY) — If the setscrew is left at the factory setting (in the heat pump position), the unit will operate in the reverse cycle heating mode. See Figure 18. When the temperature of the outdoor coil reaches 20 F (approximately 35 F outdoor air tempera- ture), the compressor will shut down as unit is no longer capable of adequate heating in heat pump mode. The electric heater then becomes the primary heating source. The electric heater remains on until the temperature of the outdoor coil reaches 40 F; then the electric heater is shut off and the compressor is energized. Once the compressor is energized, the heat pump again becomes the primary heating source.

To set unit to operate in electric heat mode only, turn the setscrew to the electric heat position. See Figure 18.

IMPORTANT: If setscrew on standard heat pump unit is set to electric heat mode operation, the com- pressor is disabled for both heating and cooling operations. If setscrew on heat pump unit with wall thermostat control is set to electric heat mode operation, the compressor will be disabled only for heating operation.

OPERATING MODES (See Figures 19

and 20.)

OUTSIDE AIR — To bring outside air into occupied space, turn the vent handle to the full open position. See Figure 17.

OFF — The OFF mode terminates unit operation.

FAN— The FAN mode will circulate air in the space at high speed and at high or low speed for cooling only models.

HIGH HEAT OR HIGH COOL — Select mode and rotate temperature knob to desired comfort level. This function provides maximum heating or cooling, and is recommended to raise or lower the room temperature quickly.

LOW HEAT OR LOW COOL — Select mode and rotate temperature knob to desired comfort level. This function provides minimum heating or cooling with maximum dehumidification and quietest operation.

FAN SPEED CONTROL FOR 52P AND 52C WALL THERMOSTAT MODELS — For maximum comfort, fan speed is user selectable at the unit. See Figure 20.

FIGURE 19 — 52P UNIT CONTROLS SHOWN

FIGURE 20 — 52P UNIT WITH

 

WALL THERMOSTAT CONTROL SHOWN

 

(Blank Plate)

10

Image 10
Contents Contents Packaged Terminal AIR Conditioners Heat PumpsUnit Inspection GeneralFront Panel Model Number Nomenclature ALL Units Electrical DataVoltage Supply Installation Chassis InstallationRemove Existing Baffles on Competitive Outdoor Grilles Unit Gaskets Tube Sheets Wall Thermostat Installation Reinstall terminal connector Restore power to unitOperation Comfort ControlsOperating Controls Operating Modes See FiguresCare and Maintenance INDOOR-AIR Inlet FiltersExternal Parts Internal PartsPreventative Maintenance Troubleshooting Possible Causes Solutions Unit does not StartAccessories Accessory Form Number Part Number DescriptionPage Carrier Carrier Corporation Corporación Carrier Carrier Garantía para Page Accesorios Retoque de PinturaProblemas DE Solución DE Tabla Soluciones Posibles CausasPreventivo Mantenimiento Scroll Y Wheel Blower 23 Figura Internas Partes MagnetoExternas Partes Vent Exterior Filtro 22 FiguraInterior Aire DE Filtro Unidad Filtro DE Remocion 21 FiguraSeries Premier Operación DE ControlTesting Confort DE ControlesTerminal DE Conector DE Reemplazo Y Remoción 15 Figura Pared DE Termostato DE InstalaciónEléctricas Conexiones 16 Figura Control DE Panel Terminales DE Cubierta 14 FiguraEspuma Hule DE TIRAS- 12 Figura Chasis DE Montaje -13 FiguraSheets Tube Ventilacion DE Puerta LA ENGE Metalico Gabinete DEL Completa Instalación Figura KIT Baffle AccesorioGE Plastico Gabinete DEL Inferior Sello EL Remueva 8 Figura Metal DE Clip EL RemuevaUnidad DE Componentes Chasis DEL InstalacionReemplazo DE Gabinetes 3 Tabla Unidades LAS Todas Para Volts 265 250, Fusibles Y Receptáculos DE Tipos TablaCandado CON Modelo DE Numero DE Nomenclatura 3 FiguraControl DE Panel DEL Instalación 4 Figura Frontal Panel EL Removiendo 2 Figura Unidad LA DE InspeccionIntroduccion Datos DE Placa DE Ejemplo 1 FiguraSeries

52P specifications

The Carrier 52P is a high-performance air conditioning unit that has gained popularity for its reliability and efficiency. Designed for both residential and commercial applications, the 52P is known for its superior cooling capabilities and energy-saving features, making it an attractive choice for temperature control in diverse environments.

One of the standout features of the Carrier 52P is its advanced inverter technology. This technology allows the compressor to operate at variable speeds, adjusting its output to maintain the desired temperature with minimal energy consumption. This not only leads to significant energy savings but also ensures a consistent and comfortable indoor climate without the fluctuations often associated with traditional systems.

The Carrier 52P is equipped with a highly efficient rotary compressor that enhances overall performance. This compressor is designed for quiet operation, ensuring that noise levels are kept to a minimum, which is especially valuable in residential settings where noise can disrupt daily activities. Additionally, the unit is designed with a high SEER (Seasonal Energy Efficiency Ratio) rating, further emphasizing its energy-efficient nature.

In terms of design, the Carrier 52P features a modern and sleek exterior, allowing it to blend seamlessly with various architectural styles. Its compact size makes it easy to install in tight spaces while still offering robust cooling capabilities. The unit is also built with durable materials to withstand a range of weather conditions, ensuring long-lasting performance.

The 52P incorporates a sophisticated air filtration system that helps improve indoor air quality by trapping dust, allergens, and other particles. This is particularly beneficial for allergy sufferers or individuals with respiratory conditions, as it promotes healthier living environments.

Further enhancing user convenience, the Carrier 52P comes with smart connectivity options, allowing users to control their systems remotely via smartphone apps. This feature enables homeowners to adjust temperatures and monitor energy usage, providing enhanced control and flexibility.

In summary, the Carrier 52P is a technologically advanced air conditioning unit that emphasizes energy efficiency, quiet operation, and modern design. Its inverter technology and high SEER rating make it an excellent choice for those looking to reduce their energy bills while maintaining a comfortable indoor environment. With its user-friendly features and reliable performance, the Carrier 52P stands out in the market for air conditioning solutions.