Micron Technology AU8000 manual Coverage of Sprayer

Page 11

9

Fig. 3 – Coverage of Sprayer

3.Calculate the area treated by the sprayer per minute. Fig. 3 shows the sprayer being operated over a field crop.

If the operator is walking at S Km/Hr this corresponds to 1000 x S metres/hour:

Distance travelled

=

1000 x S

metres/minute

 

 

60

 

If the width of the swath is W metres, then the area treated per minute is:

Area treated

=

1000 x S x W

 

sq metres/minute

 

 

60

 

 

 

This is converted to hectares by dividing by 10,000:

 

Area treated

=

1000 x S x W

=

S x W

ha/minute

 

 

60 x 10,000

 

600

 

This gives the standard formula for calculating the coverage of a sprayer:

Area/min

=

Swath Width (m) x Speed (Km/Hr)

ha/min

 

 

600

 

MICRONAIR AU8000 SPRAYER

Image 11
Contents Sprayer Table of Contents Tank and Blower SpecificationIntroduction AU8000 SprayheadAssembly Operation of Standard Sprayer OperationMicronair AU8000 Sprayer Controls for Pump and Suction Filling Valve Operation of Sprayer with Chemical PumpOperation of Sprayer with Filling Pump Health and SafetyMicronair AU8000 Sprayer Output Rate of Chemical CalibrationCoverage of Sprayer Swath Width Metres Litre/tree Adjustment of Droplet Size Setting Marks on Blade MaintenancePossible Engine Faults and Remedies Knapsack Mistblower Routine MaintenanceUnsteady Engine RPM or Tendency to Stop Maintenance of Sprayhead Micronair AU8000 Sprayer Description Quantity Parts ListsAU8000 Sprayhead AU8000 Atomiser AU8000 Atomiser Conversion Factors