Installation
E F G
H J
A
B
C
D
KEY
K
M
L
AElectrically Conductive Air Hose
B | Female Quick Disconnect Coupler | N |
C | Male Quick Disconnect Fitting |
|
DAir Line Filter
EAir Regulator and Gauge
F
GAir Line Lubricator
HPump Runaway Valve
JPump Air Inlet
K | Ground Wire |
| 1/2 in. |
L | Pressure Drain Valve |
| (13 mm) |
M | Electrically Conductive Fluid Hose |
| |
|
|
NSpray Gun
Fig. 1
04209
NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawings.
Figure 1 is only a guide to selecting and installing optional and required accessories. For help in design- ing a system to suit your needs, contact your Graco distributor.
Mount the pump to suit the type of installation planned. See page 23 for dimensions and mounting hole layout.
System Accessories
WARNING
To reduce the risk of serious injury including skin injection, splashing in the eyes or on the skin, and injury from moving parts, if you are adjusting or repairing the pump, two accessories are required in your system: a
The
The pressure drain valve (L) assists in relieving fluid pressure in the displacement pump, hoses and gun. Triggering the spray gun to relieve pres- sure may not be sufficient.