Haier 309463N important safety instructions Technical Data, Category Data

Page 26

Technical Data

Technical Data

Category

Data

Maximum fluid working pressure

Part No. 233891, 233896, 233901, 233906, 233911, 233916, 233921, 233926,

 

288120, 288123: 1500 psi (10.5 MPa, 105 bar)

 

Part No. 233892, 233897, 233902, 233907, 233912, 233917, 233922, 233927:

 

2000 psi (14.0 MPa, 140 bar)

 

Part No. 233893, 233894, 233898, 233899, 233903, 233904, 233908, 233909,

 

233913, 233914, 233918, 233919, 233923, 233924, 233928, 233929, 234725,

 

234727:

 

3000 psi (21.0 MPa, 210 bar)

 

Part No. 233895, 233900, 233905, 233910, 233915, 233920, 233925, 233930,

 

234726, 234728: 4000 psi (28.0 MPa, 280 bar)

Maximum air input pressure

100 psi (0.7 MPa, 7 bar)

Minimum air input pressure

7 psi (0.05 MPa, 0.5 bar)

Ratio

Part No. 233891, 233896, 233901, 233906, 233911, 233916, 233921, 233926,

 

288120, 288123: 15:1

 

Part No. 233892, 233897, 233902, 233907, 233912, 233917, 233922, 233927:

 

20:1

 

Part No. 233893, 233894, 233898, 233899, 233903, 233904, 233908, 233909,

 

233913, 233914, 233918, 233919, 233923, 233924, 233928, 233929, 234725,

 

234727:

 

30:1

 

Part No. 233895, 233900, 233905, 233910, 233915, 233920, 233925, 233930,

 

234726, 234728: 40:1

Operating temperature range

50-160°F (10-71°C)

Wetted parts

Pump: See manual 309462.

 

Gun (if present): See manual 311001 or 306686.

 

Fluid Filter (if present): See manual 307273.

 

Fluid Hoses (if present): stainless steel, nylon

 

Suction Tube: synthetic rubber, nylon, stainless steel

26

309463N

Image 26
Contents Merkur Spray Packages II 2 GContents Model Information Wall Mount SprayersCart Mount Sprayers Equipment Misuse Hazard Fire and Explosion Hazard 309463N General Information InstallationInstall the Muffler GroundingTypical Installation Key Wall Mount Packages Air Line AccessoriesFluid Line Accessories Fluid Inlet FittingInstalling a Fluid Regulator accessory Fluid Regulator on Package Without Fluid FilterPressure Relief Procedure OperationStarting and Adjusting the Pump Shutdown and Care of the PumpFlush the Equipment Maintenance Troubleshooting Problem Cause SolutionCutaway View of Merkur Pump Parts Ground Wire and Clamp Part No. Description QtyCart Mount Packages Cart Mount Packages Air Inlet Details Air Inlet Adapter, used on 233896 through Hose and Gun Details Used on Models 233906, 233916, 233926, 288120 Part No. Description Qty 200 HOSE, cpld Mm 1/4 in. SSTTechnical Data Category DataWall Mount Sprayers Cart Mount Sprayers Wall Mount DimensionsPackage Weights Toll Free Graco Standard WarrantyGraco Information