Haier 309463N Installation, General Information, Grounding, Install the Muffler

Page 8

Installation

Installation

General Information

• Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing.

Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and pressure-rated for your system.

FIG. 2 is a guide for selecting and installing system components and accessories. It is not an actual system design. Contact your Graco distributor for assistance in designing a system to suit your particular needs.

2.Air and fluid hoses: use only electrically conductive hoses.

3.Air compressor: follow manufacturer's recommen- dations.

4.Spray gun: ground through connection to a properly grounded fluid hose and pump.

5.Fluid supply container: follow your local code.

6.Object being sprayed: follow your local code.

7.Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or card- board, which interrupts the grounding continuity.

Grounding

WARNING

Before operating the pump, ground the system as explained below. Read the warnings on page 6.

1.Pump: use Part No. 238909 Ground Wire and Clamp (supplied). See FIG. 1. Insert one end of the ground wire (Y) into the pump’s grounding clamp (X) and tighten the screw (W) securely. Connect the other end of the wire to a true earth ground.

Y

X

W

ti1930a

FIG. 1. Grounding Wire

TI1102

TI1102

8.To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

Install the Muffler

The muffler (C, FIG. 2) is shipped loose. Screw the muf- fler into the muffler port before installing the pump.

Air and Fluid Hoses

See FIG. 2. Be sure all air hoses (A, P) and fluid hoses (R, U) are properly sized and pressure-rated for your system. Use only electrically conductive hoses. Fluid hoses must have spring guards on both ends. Use a swivel (S) between the fluid hose (R) and the gun (T) to allow easier gun movement.

8

309463N

Image 8
Contents Merkur Spray Packages II 2 GContents Model Information Wall Mount SprayersCart Mount Sprayers Equipment Misuse Hazard Fire and Explosion Hazard 309463N Installation Install the MufflerGeneral Information GroundingTypical Installation Key Air Line Accessories Fluid Line AccessoriesWall Mount Packages Fluid Inlet FittingInstalling a Fluid Regulator accessory Fluid Regulator on Package Without Fluid FilterPressure Relief Procedure OperationStarting and Adjusting the Pump Shutdown and Care of the PumpFlush the Equipment Maintenance Troubleshooting Problem Cause SolutionCutaway View of Merkur Pump Parts Ground Wire and Clamp Part No. Description QtyCart Mount Packages Cart Mount Packages Air Inlet Details Air Inlet Adapter, used on 233896 through Hose and Gun Details Used on Models 233906, 233916, 233926, 288120 Part No. Description Qty 200 HOSE, cpld Mm 1/4 in. SSTTechnical Data Category DataWall Mount Sprayers Cart Mount Sprayers Wall Mount DimensionsPackage Weights Toll Free Graco Standard WarrantyGraco Information