Graco RTX 650 important safety instructions RotoFlex II Pump, Disassembly

Page 8

RotoFlexII Pump

RotoFlexII Pump

Disassembly

1.Relieve Pressure, page 6.

2.Unplug sprayer from outlet.

6.Use 3/8 in. socket to remove screw (36) from hose bracket (27).

36

ti2810b

3.Remove Shroud, page 7.

4.Loosen two spacers (56) and knob (41).

ti9065a

7.Slide hose fittings out of hose bracket (27) and remove hose (23) from base (2).

ti3084a

41

56

ti9657a

5.Loosen hopper fitting by hand to remove hopper (1). 1

ti8781a

8

Image 8
Contents Model 254973 Shown Related Manuals311777 311767 Fire and Explosion Hazard Equipment Misuse HazardElectric Shock Hazard Pressurized Equipment HazardTi9075a Component Identification ComponentPressure Relief Procedure Grounding and Electrical RequirementsAuxiliary Air Compressor Required Generator Requirements AlternateRelieve Pressure, DisassemblyReassemblyShroud Removal Disassembly RotoFlex II PumpReassembly Motor Replace two clevis pins 20 in base Motor Fuse Removal Belt Relieve Pressure, page 6. Remove TroubleshootingProblem Cause Solution Relieve Pressure, page 6. Clean Wiring Diagram Parts ModelsPart Description Qty BaseTechnical Data Graco Standard Warranty Graco Information