Graco 3A1203B 24F592 Merkur Non-Heated Circulation Kit, 24F592 Kit Parts, Mounting, Installation

Page 4

24F592 Merkur Non-Heated Circulation Kit

24F592 Merkur Non-Heated Circulation Kit

24F592 Kit Parts

Ref.

Part No. Description

Qty

5

222200

VALVE, back pressure; see 307892

1

6

168160

BUSHING; 3/8 npt(m) x 1/4 npt(f)

1

8

114339

SWIVEL, straight; 1/4 npt(m) x 1/4

1

 

 

npsm(f)

 

9

113070

NIPPLE, reducer; 3/8 npt x 1/4 npt

1

12

502851

BUSHING; 1 in. npt(m) x 3/4 npt(f)

1

13

15V521 ADAPTER, swivel, 90°; 1 in. npt(m)

1

 

 

x 1 in. npsm(f) x 1/4 npt(f)

 

14

113834

VALVE, ball, 3-way; 1/4 npt(m)

1

15

239062

HOSE; 1/4 npsm(f); nylon

1

16

256424

KIT, suction hose; with strainer

1

17

236892

SWIVEL, straight; 1/2 npt(m) x 3/8

1

 

 

npsm(f)

 

18

24B299

BUSHING; 3/4 npt(f) x 1/2 npt(m)

1

19

119400

PIPE SEALANT; 2 ml

2

20

114593

KNOB

1

22

24F658 KIT, fluid filter; see 307273

1

Mounting

Mount the pump as explained in your separate pump manual.

Installation

NOTE: Apply pipe sealant (19) to all non-swiveling threads.

NOTE: On pumps with a 3/4 npt fluid inlet, use bushing (12) to allow connection of the swivel adapter (13).

1.See FIG. 1. Assemble the bushing (12, if needed) and swivel adapter (13) to the pump inlet. Attach the suction hose kit (16) to the adapter.

2.Screw one branch of the 3-way valve (14) into the 1/4 npt port of the adapter (13). Attach the drain hose (15) to the opposite branch of the valve.

3.Assemble the knob (20), reducer nipple (9), bushing (6), and the male end of the swivel (8) to the back pressure valve (5). Screw the swivel (8) onto the middle threads of the 3-way valve.

4.Attach the fluid filter kit (22) as follows:

a.On pumps with a 3/8 npt fluid outlet, screw the female end of the swivel (17) onto the pump out- let fitting. Screw the fluid filter kit (22) inlet onto the male end of the swivel. The bushing (18) is not needed.

b.On pumps with a 3/4 npt fluid outlet, screw the female end of the bushing (18) onto the pump outlet fitting. Screw the fluid filter kit (22) inlet onto the male end of the bushing. The swivel

(17)is not needed.

c.On pumps with a 1/2 npt fluid outlet, screw the fluid filter kit (22) inlet directly onto the pump outlet fitting. The swivel (17) and bushing (18) are not needed.

5.Ground the pump as explained in your separate pump manual.

6.Connect the fluid supply line to the fitting at the fluid filter outlet.

7.Connect the fluid return line (R) to the reducer nip- ple (9) at the inlet of the back pressure valve (5). Use the back pressure valve to adjust fluid pressure in the circulation system.

8.Use the 3-way valve (14) to direct circulating fluid back to the pump through the adapter (13), or to a container through the drain hose (15).

9.See your separate pump manual for pump opera- tion, maintenance, repair, and parts information.

4

3A1203B

Image 4
Contents Flat Line Spray Systems Kits Contents 3A1203B Installation 24F592 Merkur Non-Heated Circulation Kit24F592 Kit Parts MountingF592 Merkur Non-Heated Circulation Kit 24F595 Merkur Bellows Non-Heated Circulation Kit 24F595 Kit PartsF595 Merkur Bellows Non-Heated Circulation Kit 24F595 Merkur Bellows Non-Heated Circulation Kit 24F590 120V and 24F591 240V Merkur Heated Circulation Kit 24F590 and 24F591 Kit PartsInstallation F590 and 24F591 Merkur Heated Circulation Kit 24F590 120V and 24F591 240V Merkur Heated Circulation Kit 24F593 and 24F594 Kit Parts Installation F593 and 24F594 Merkur Bellows Heated Circulation Kit G25NXT and G45NXT Dura-Flo Pump G25NXT and G45NXT Kit PartsWall Bracket Mounting Hole Diagrams Merkur Wall BracketKit Mounting Bracket Diagrams Technical Data Graco Standard Warranty Graco Information