24F592 Merkur
24F592 Merkur Non-Heated Circulation Kit
24F592 Kit Parts
Ref. | Part No. Description | Qty | |
5 | 222200 | VALVE, back pressure; see 307892 | 1 |
6 | 168160 | BUSHING; 3/8 npt(m) x 1/4 npt(f) | 1 |
8 | 114339 | SWIVEL, straight; 1/4 npt(m) x 1/4 | 1 |
|
| npsm(f) |
|
9 | 113070 | NIPPLE, reducer; 3/8 npt x 1/4 npt | 1 |
12 | 502851 | BUSHING; 1 in. npt(m) x 3/4 npt(f) | 1 |
13 | 15V521 ADAPTER, swivel, 90°; 1 in. npt(m) | 1 | |
|
| x 1 in. npsm(f) x 1/4 npt(f) |
|
14 | 113834 | VALVE, ball, | 1 |
15 | 239062 | HOSE; 1/4 npsm(f); nylon | 1 |
16 | 256424 | KIT, suction hose; with strainer | 1 |
17 | 236892 | SWIVEL, straight; 1/2 npt(m) x 3/8 | 1 |
|
| npsm(f) |
|
18 | 24B299 | BUSHING; 3/4 npt(f) x 1/2 npt(m) | 1 |
19 | 119400 | PIPE SEALANT; 2 ml | 2 |
20 | 114593 | KNOB | 1 |
22 | 24F658 KIT, fluid filter; see 307273 | 1 |
Mounting
Mount the pump as explained in your separate pump manual.
Installation
NOTE: Apply pipe sealant (19) to all
NOTE: On pumps with a 3/4 npt fluid inlet, use bushing (12) to allow connection of the swivel adapter (13).
1.See FIG. 1. Assemble the bushing (12, if needed) and swivel adapter (13) to the pump inlet. Attach the suction hose kit (16) to the adapter.
2.Screw one branch of the
3.Assemble the knob (20), reducer nipple (9), bushing (6), and the male end of the swivel (8) to the back pressure valve (5). Screw the swivel (8) onto the middle threads of the
4.Attach the fluid filter kit (22) as follows:
a.On pumps with a 3/8 npt fluid outlet, screw the female end of the swivel (17) onto the pump out- let fitting. Screw the fluid filter kit (22) inlet onto the male end of the swivel. The bushing (18) is not needed.
b.On pumps with a 3/4 npt fluid outlet, screw the female end of the bushing (18) onto the pump outlet fitting. Screw the fluid filter kit (22) inlet onto the male end of the bushing. The swivel
(17)is not needed.
c.On pumps with a 1/2 npt fluid outlet, screw the fluid filter kit (22) inlet directly onto the pump outlet fitting. The swivel (17) and bushing (18) are not needed.
5.Ground the pump as explained in your separate pump manual.
6.Connect the fluid supply line to the fitting at the fluid filter outlet.
7.Connect the fluid return line (R) to the reducer nip- ple (9) at the inlet of the back pressure valve (5). Use the back pressure valve to adjust fluid pressure in the circulation system.
8.Use the
9.See your separate pump manual for pump opera- tion, maintenance, repair, and parts information.
4 | 3A1203B |