24F590 (120V) and 24F591 (240V) Merkur Heated Circulation Kit
24F590 (120V) and 24F591 (240V) Merkur Heated Circulation Kit
24F590 and 24F591 Kit Parts
Ref. | Part No. Description | Qty | |
1 | 24A590 | BRACKET | 1 |
2 | 115643 | SCREW; machine, hex washer hd; | 8 |
|
| M8 x 25 mm |
|
3 | 114874 | SWIVEL, 90°; 1/2 npt(m) x 1/2 | 1 |
|
| npsm(f) |
|
4 | 245848 | HEATER, fluid, 120V; for 24F590; | 1 |
|
| see 309524 |
|
| 245863 | HEATER, fluid, 240V; for 24F591; | 1 |
|
| see 309524 |
|
5 | 222200 | VALVE, back pressure; see 307892 | 1 |
6 | 168160 | BUSHING; 3/8 npt(m) x 1/4 npt(f) | 1 |
7 | 100527 | WASHER, plain; 0.312 in. ID | 4 |
8 | 114339 | SWIVEL, straight; 1/4 npt(m) x 1/4 | 1 |
|
| npsm(f) |
|
9 | 113070 | NIPPLE, reducer; 3/8 npt x 1/4 npt | 1 |
10 | 104541 | NUT, lock; M8 | 4 |
12 | 502851 | BUSHING; 1 in. npt(m) x 3/4 npt(f) | 1 |
13 | 15V521 | ADAPTER, swivel, 90°; 1 in. npt(m) | 1 |
|
| x 1 in. npsm(f) x 1/4 npt(f) |
|
14 | 113834 | VALVE, ball, | 1 |
15 | 239062 | HOSE; 1/4 npsm(f); nylon | 1 |
16 | 256424 | KIT, suction hose; with strainer | 1 |
17 | 236892 | SWIVEL, straight; 1/2 npt(m) x 3/8 | 1 |
|
| npsm(f) |
|
18 | 24B299 | BUSHING; 3/4 npt(f) x 1/2 npt(m) | 1 |
19 | 119400 | PIPE SEALANT; 2 ml | 2 |
20 | 114593 | KNOB | 1 |
21 | 114373 | NIPPLE; 1/2 npt | 1 |
22 | 24F658 | KIT, fluid filter; see 307273 | 1 |
25 | 24C406 | HOSE, fluid; 1/2 npsm(fbe) x 3 ft | 1 |
|
| (0.9 m) |
|
Mounting
NOTE: See your separate pump and heater manuals. Be sure the wall can support the weight of the pump, heater, brackets, hoses and accessories, as well as the stress caused during operation. Hole diameters and wall mounting dimensions are shown on page 17. Kit mount- ing bracket diagrams are shown on page 18.
1.See FIG. 3. Remove the screws (S) holding the wall bracket (B) to the pump (P). Set the pump aside. Keep the screws and bracket.
2.Orient the bracket (1) as shown, and assemble to the wall bracket (B) with four screws (2), washers (7), and nuts (10).
3.Position the wall bracket (B) at a convenient height, so the 3 ft (0.9 m) suction hose (16) will not be stretched tight; letting the hose hang assists fluid flow into the pump. For ease of operation and ser- vice, make sure the pump air inlet, fluid inlet, and fluid outlet ports are easily accessible.
4.Using the wall bracket (B) as a template, drill mount- ing holes in the wall.
5.Attach the bracket (B) to the wall. Use screws that are long enough to keep the pump from vibrating during operation.
NOTE: Be sure the bracket is level.
6.Mount the pump (P) to the bracket (1) using the four screws (S) removed in step 1.
7.Remove the screws and washers from the heater mounting posts and discard. Mount the heater (4) to the bracket (1) using four screws (2).
3A1203B | 9 |