Optional Configurations
Optional Configurations
Optional Fluid Manifold | 6. Attach fluid manifold. Connect air. Return gun to | |
Position | ||
service. | ||
Fluid manifold is mounted to bottom of gun, with A side |
| |
on left, viewed from operator’s position at back of gun. If |
| |
desired, manifold may be moved to top of gun. Doing |
| |
this will reposition A side parts (fluid inlet swivel, check |
| |
valve, side seal cartridge, and mix chamber) to right. |
| |
|
| |
CAUTION |
| |
To prevent |
| |
do not interchange A component (isocyanate) and B |
| |
component (resin) parts. |
| |
|
| |
1. Follow Pressure Relief Procedure, page 15. |
| |
2. Disconnect air (D) and remove fluid manifold (M). |
|
M
D
TI2554A
3. Remove Front End, page 27.
4. Rotate fluid housing 180°.
5. Attach Front End, page 28.
16 | 309550Y |