Graco Inc 247936, 312900C, 247937 Check Electrical Grounding, Check Fluid Resistivity

Page 15

Check Electrical Grounding

Fire, Explosion, and Electric Shock Hazard

Megohmmeter Part No. 241079 (AA-see FIG. 7.) is not approved for use in a hazardous area. To reduce the risk of sparking, do not use the megohmmeter to check electrical grounding unless:

The gun has been removed from the hazardous area;

Or all spraying devices in the hazardous area are turned off, ventilation fans in the hazardous area are operating, and there are no flammable vapors in the area (such as open solvent containers or fumes from spraying).

Failure to follow this warning could cause fire, explo- sion, and electric shock and result in serious injury and property damage.

1.Have a qualified electrician check the electrical grounding continuity of the spray gun and air hose.

2.Turn the ES ON/OFF valve OFF.

3.Turn off the air and fluid supply to the gun. The fluid hose must not have any fluid in it.

4.Make sure the grounded air hose (R) is connected and the hose ground wire is connected to a true earth ground.

ti1259a

5.Measure the resistance between the gun handle (BB) and a true earth ground (CC). Use an applied voltage of 500 minimum to 1000 volts maximum. The resistance should not exceed 1 megohm. See FIG. 7.

6.If the resistance is greater than 1 megohm, check the tightness of the ground connections and be sure the air hose ground wire is connected to a true earth ground. If the resistance is still too high, replace the air hose.

Installation

BB

AA

CC

ti1274a

Fig. 7. Check Gun Grounding

Check Fluid Resistivity

Fire, Explosion, and Electric Shock Hazard

Check the fluid resistivity in a non-hazardous area only. Resistance Meter 722886 and Probe 722860 are not approved for use in a hazardous area.

Failure to follow this warning could cause fire, explo- sion, or electric shock and result in serious injury and property damage.

Graco Part No. 722886 Resistance Meter and 722860 Probe are available as accessories to check that the resistivity of the fluid being sprayed meets the require- ments of an electrostatic air spray system.

Follow the instructions included with the meter and probe. If the material is above 1 megohm-cm, then a Pro Xs3 HC gun may be a better option. The Pro Xs WB gun is intended to spray very conductive waterborne materi- als and other materials less than 1 megohm-cm.

312900C

15

Image 15
Contents II 2 G EEx 0.24 mJ PRO Xs Waterborne Air Spray GunTable of Contents FIRE, EXPLOSION, and Electric Shock Hazard Equipment Misuse Hazard Standard Model 247936 OverviewHow the Electrostatic Air Spray Gun Works Smart Model 247937Air swivel inlet. Left-hand thread Fan air adjustment valve. Adjusts fan size ES indicator 247936 only. Green when ES is on Installation Install the SystemVentilate the Spray Booth Typical Installation Key Connect the Air Line Connect the Charging ProbeGrounded Air Supply Hose Connect the Exhaust Tube Connect the Fluid LineFilter the Fluid Orifice Size Select a Fluid Nozzle and Air CapFire, Explosion, and Electric Shock Hazard GroundingCheck Fluid Resistivity Check Electrical GroundingPrepare to Paint Check Fluid ViscosityTurn ES ON/OFF switch on Flush Pressure Relief ShutdownPressurized Equipment Hazard Clean Gun Daily MaintenanceDaily System Care See Check Electrical Grounding on Electrical TroubleshootingElectric Shock Hazard See Test Total Gun Resistance onTest Charging Probe Resistance Electrical TestsTest Gun Resistance Test Total Gun ResistanceTest Barrel Resistance Test Power Supply ResistanceSpray Pattern Troubleshooting Gun Operation Troubleshooting Prepare the Gun for Repair Gun RepairReplace Fluid Needle Replace Air Cap/NozzleRemove Fluid Packing Remove Fluid PackingPacking Rod Repair Packing RodRemove Barrel Install BarrelPower Supply Remove and Replace Power SupplyRemove and Replace Turbine Alternator Repair Fan Air Adjustment ValveRepair Air Valve Repair Fluid Adjustment ValveRepair ES ON/OFF Valve Remove and Replace Atomizing Air Restrictor ValveParts Part No 60 kV Electrostatic Gun, Series a Standard modelRef. No Multi-tool Part No 60 kV Electrostatic Gun, Series a Smart model Smart Model controls Ref. No Alternator Ref. No Fan Adjustment ValveRef. No Packing Rod Ref. No ES ON/OFF ValveDescription Qty Description Qty Accessories Air Line AccessoriesFluid Line Accessories Miscellaneous Accessories Gun AccessoriesCategory Data Technical DataGraco Information Graco Warranty