Graco Inc 312900C, 247936, 247937 important safety instructions Remove Barrel, Install Barrel

Page 31

Remove Barrel

1.Prepare the gun for repair, page 27.

2.Carefully loosen the nut (54) from the bracket fluid fitting (13). Pull the tube (14 or 50a) out of the fitting. Make sure both ferrules and the nut stay with the tube.

3.Loosen the three screws (11).

NOTICE

To avoid damaging the power supply (18), pull the gun barrel straight away from the gun handle. If necessary, gently move the gun barrel from side to side to free it from the gun handle.

4.Hold the gun handle (17) with one hand and pull the barrel (16) straight off the handle. See FIG. 16.

32

54 14

55

13

1116

ti1503a

17

ti1504a

Fig. 16. Remove Barrel

Gun Repair

Install Barrel

1.Be sure the gasket (10*) and grounding spring (53) are in place. Make sure the air holes are aligned properly. Replace if damaged. See FIG. 17.

2.Place the barrel (16) over the power supply (18) and onto the gun handle (17).

3.Tighten the three screws (11) oppositely and evenly (about a half turn past snug).

NOTICE

Do not over-tighten the screws (11).

4.Assemble the fluid tube (14) into the bracket fitting (13). Ensure that the ferrules are in place. Tighten the nut (54).

5.Test gun resistance, page 23.

*10 18

11

16

53

ti12830

Fig. 17. Install Barrel

312900C

31

Image 31
Contents II 2 G EEx 0.24 mJ PRO Xs Waterborne Air Spray GunTable of Contents FIRE, EXPLOSION, and Electric Shock Hazard Equipment Misuse Hazard Standard Model 247936 OverviewHow the Electrostatic Air Spray Gun Works Smart Model 247937Air swivel inlet. Left-hand thread Fan air adjustment valve. Adjusts fan size ES indicator 247936 only. Green when ES is on Install the System InstallationVentilate the Spray Booth Typical Installation Key Connect the Charging Probe Connect the Air LineGrounded Air Supply Hose Connect the Fluid Line Connect the Exhaust TubeFilter the Fluid Orifice Size Select a Fluid Nozzle and Air CapFire, Explosion, and Electric Shock Hazard GroundingCheck Fluid Resistivity Check Electrical GroundingPrepare to Paint Check Fluid ViscosityTurn ES ON/OFF switch on Flush Shutdown Pressure ReliefPressurized Equipment Hazard Clean Gun Daily MaintenanceDaily System Care See Check Electrical Grounding on Electrical TroubleshootingElectric Shock Hazard See Test Total Gun Resistance onTest Charging Probe Resistance Electrical TestsTest Gun Resistance Test Total Gun ResistanceTest Barrel Resistance Test Power Supply ResistanceSpray Pattern Troubleshooting Gun Operation Troubleshooting Prepare the Gun for Repair Gun RepairReplace Fluid Needle Replace Air Cap/NozzleRemove Fluid Packing Remove Fluid PackingPacking Rod Repair Packing RodRemove Barrel Install BarrelPower Supply Remove and Replace Power SupplyRemove and Replace Turbine Alternator Repair Fan Air Adjustment ValveRepair Air Valve Repair Fluid Adjustment ValveRepair ES ON/OFF Valve Remove and Replace Atomizing Air Restrictor ValvePart No 60 kV Electrostatic Gun, Series a Standard model PartsRef. No Multi-tool Part No 60 kV Electrostatic Gun, Series a Smart model Smart Model controls Ref. No Alternator Ref. No Fan Adjustment ValveRef. No Packing Rod Ref. No ES ON/OFF ValveDescription Qty Description Qty Air Line Accessories AccessoriesFluid Line Accessories Miscellaneous Accessories Gun AccessoriesCategory Data Technical DataGraco Information Graco Warranty