Carrier 38MVQ, 40MVQ 38MVC012--- --- ---3 Control Board, 40MVC012--- --- ---3 Control Board

Page 40

38/40MVC, MVQ

A3 - 53MVC012----

3

 

 

 

 

 

 

38MVC012--- --- ---3 CONTROL BOARD

CONNECTOR

 

INPUT or OUTPUT VALUE

CN2

OUT: (Pin 1: Pulse 0 to 12 Volts DC) (Pin2: 35±2 Volts DC) (Pin 3: GND) (Pin 4: 13±4 Volts DC) all relative to Pin 3

CN3

OUT:

L2 208/230 Volt AC

 

CN4

IN:

L2 208/230 Volt AC

 

CN9

OUT:

L1 208/230 Volt AC

 

CN10

IN:

L1 208/230 Volt AC

 

P1

Ground

 

P2

Ground

 

 

 

40MVC012--- --- ---3 CONTROL BOARD

CONNECTOR

 

INPUT or OUTPUT VALUE

CN1

IN: 0--- 5 Volt DC

 

CN2

IN: 0--- 5 Volt DC

 

CN3

Pulse drive output: 0--- 17 Volts DCPin 5: GND

All other Pins are 0 to 17 Volt DC) All relative to Pin 5)

CN5

Power Output: (Pin 1: GND) (Pin 2: 5 Volts DC)

Input: (Pin 3: Pulse 0 to 5 Volts DC) Output:(Pin 4~ Pin 10: Pulse 0 to 5

Volt DC) All relative to Pin 1

 

 

 

CN6

Out: (Pin 1: 35 Volt DC) ( Pin 2: Empty) (Pin 3: GND) (Pin 4: 5 Volt DC) (Pin 5: Pulse 0--- 5 Volt DC) IN: (Pin 6: Pulse 0 to 5

Volt DC) All relative to Pin 3

 

 

 

G1

IN: (Pin 1: Pulse 0 to 12 Volts DC) (Pin2: 35±2 Volts DC) (Pin 3: GND) (Pin 4: 13±4 Volts DC) all relative to Pin 3

A4 - 53MVQ012----

3

 

 

 

 

 

 

38MVQ012--- --- ---3 CONTROL BOARD

CONNECTOR

 

INPUT or OUTPUT VALUE

CN1

OUT: (Pin 1: GND, Pin 2: 5 Volts DC, Pin 3: Empty) IN: (Pin 4: 0 to 5 Volts DC) All relative to Pin 1

CN2

OUT: (Pin 1: Pulse 0 to 12 Volts DC) (Pin2: 35±2 Volts DC) (Pin 3: GND) (Pin 4: 13±4 Volts DC) all relative to Pin 3

CN3

OUT:

L2 208/230 Volt AC

 

CN4

IN:

L2 208/230 Volt AC

 

CN5

OUT:

L1 208/230 Volt AC

 

CN6

OUT:

L1 208/230 Volt AC

 

CN10

IN:

L1 208/230 Volt AC

 

P1

Ground

 

P2

Ground

 

 

 

40MVQ012--- --- ---3 CONTROL BOARD

CONNECTOR

 

INPUT or OUTPUT VALUE

CN1

IN: 0--- 5 Volt DC

 

CN2

IN: 0--- 5 Volt DC

 

CN3

Pulse drive output: 0--- 17 Volts DCPin 5: GND

All other Pins are 0 to 17 Volt DC) All relative to Pin 5

CN5

Power Output: (Pin 1: GND) (Pin 2: 5 Volts DC)

Input: (Pin 3: Pulse 0 to 5 Volts DC) Output:(Pin 4~ Pin 10: Pulse 0 to 5

Volt DC) All relative to Pin 1

 

 

 

CN6

Out: (Pin 1: 35 Volt DC) ( Pin 2: Empty) (Pin 3: GND) (Pin 4: 5 Volt DC) (Pin 5: Pulse 0--- 5 Volt DC) IN: (Pin 6: Pulse 0 to 5

Volt DC) All relative to Pin 3

 

 

 

G1

IN: (Pin 1: Pulse 0 to 12 Volts DC) (Pin2: 35±2 Volts DC) (Pin 3: GND) (Pin 4: 13±4 Volts DC) all relative to Pin 3

40

Image 40
Contents 38MVC/40MVC 38MVQ/40MVQ IntroductionModel Number Nomenclature Indoor UnitStandard Features and Accessories System Model Number Specifications Cooling only UnitsCoil Specifications Heat Pump Units OutdoorService Valve Locations Clearances Indoor System Operating Envelope 53MVC/MVQ System Operating Envelope ChartElectrical Data Connection Diagrams Connection DiagramsWiring Diagrams Wiring Diagram 38MVC009----1 W/ 40MVC009----1Wiring Diagram 38MVC012----1 W/ 40MVC012----1 Wiring Diagram 38MVC012----3 W/ 40MVC012----3 Wiring Diagram 38MVC018----3 W/ 40MVC018----3 Wiring Diagram 38MVQ009----1 W/ 40MVQ009----1 Wiring Diagram 38MVQ012----1 W/ 40MVQ012----1 Wiring Diagram 38MVQ012----3 W/ 40MVQ012----3 Refrigeration Cycle Diagram CoolingGeneral refrigerant line sizing Refrigerant LinesRefrigerant Charge Using Vacuum Pump System Evacuation and ChargingMinute Time Delay Control SystemSystem Safeties Compressor Overcurrent ProtectionCondenser High Temperature Protection Indoor High Temperature ProtectionSequence of Operation Indoor Coil Freeze ProtectionModes of Operation Auto Fan DefrostManual Operation Dry Dehumidification ModeForced Cooling Operation Troubleshooting Diagnostic HierarchyRequired Tools Recommended StepsChart 1 Indoor FAN Speed OUT of Control YesChart 2 Temperature Sensor Chart 3 Compressor Overcurrent Protection Chart 4 Indoor Unit Communication Error Size 9K and 12K Chart 5 Outdoor Unit Protects Chart 6 Indoor Unit Communication Error Size 18K and 24K Chart 7 Unit not RUNNING, no Diagnostic Code Chart 8 Unit not Running Optimally Chart 9 Unit not Running Optimally HP in Heating Chart 10 Compressor Chart 11 Outdoor Motor Chart 12 Reversing Valve Chart 13 Receiver BoardAppendix Table of Contents Description Number Appendix38MVC009--- --- ---1/38MVC012--- --- ---1 Control Board Input or Output Value40MVC009--- --- ---1/40MVC012--- --- ---1 Control Board 38MVQ009---1/38MVQ012--- --- ---1 Control Board38MVC012--- --- ---3 Control Board 40MVC012--- --- ---3 Control Board38MVQ012--- --- ---3 Control Board 40MVQ012--- --- ---3 Control Board38MVC018--- --- ---3 Control Board Control BoardA6 Characteristics of Temperature Sensor Temp. ˚F/˚C Resistance KΩ9K & 12K Units 18K & 24K UnitsCatalog No.38---40MV---1SM
Related manuals
Manual 10 pages 47.7 Kb

40MVQ, 40MVC, 38MVQ, 38MVC specifications

The Carrier 38MVC, 38MVQ, 40MVC, and 40MVQ are advanced air-conditioning systems designed for both residential and commercial applications. These units are recognizable for their commitment to efficiency, reliability, and comfort, making them ideal choices for various environments.

One of the standout features of these models is their high energy efficiency ratings. Both the 38MVC and 38MVQ boast Seasonal Energy Efficiency Ratios (SEER) that exceed industry standards, delivering substantial energy savings over time. The 40MVC and 40MVQ models also continue this trend, featuring enhanced efficiency that translates into lower utility bills and a reduced carbon footprint.

These air-conditioning units utilize Carrier's innovative inverter technology, which allows for variable speed operation. This means that the compressor can adjust its speed according to the cooling demand, resulting in smoother temperature control and less energy consumption. The inverter technology not only maximizes comfort but also contributes to quieter operation, as the systems can run at lower speeds when full capacity is not required.

In addition to efficiency, the Carrier 38MVC, 38MVQ, 40MVC, and 40MVQ are equipped with advanced filtration systems. These systems work to purify the air by reducing allergens and pollutants, ensuring a healthier indoor environment. Some models also come equipped with smart connectivity options, allowing users to control their air conditioning remotely via a smartphone app. This feature adds convenience and helps monitor energy usage effectively.

With durable construction and high-quality components, these units are designed to withstand the test of time, reducing the need for frequent repairs or replacements. They are also built to operate quietly, so they can provide comfort without disturbing the peace of the indoor environment.

In terms of installation flexibility, the Carrier 38MVC, 38MVQ, 40MVC, and 40MVQ can be easily integrated into various existing HVAC systems, thanks to their compatible size and design. This adaptability makes them suitable for a wide range of applications, from small residential homes to larger commercial spaces.

Overall, the Carrier 38MVC, 38MVQ, 40MVC, and 40MVQ models are engineered with cutting-edge technologies that prioritize efficiency, comfort, and ease of use, making them an excellent choice for those looking to enhance their indoor climate control solutions.