Graco Inc 236-870, 308-230, 236-628, 236-868, 236-414, 236-869 Technical Data, Manual Change Summary

Page 19

Technical Data

Wetted Parts

Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See 308–553 Pail Cover (236–870, 224–833,

236–412) . . . . . . . . . . . . . . . . . . . . . . . . . . . stainless steel Fluid Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . nylon Hose Couplings . . . . . . . . . . . . . . . . . . . . . . . stainless steel Surge Tank (236–412, 236–414, 236–628, 236–868, 236–869) . . . . . . nylon, EPDM or Vitonr, stainless steel Fluid Regulator (236–870, 224–833) . . . . . . See 308–325 Fittings . . . . . . . . . . . . . . . . . . . . . . . . acetal, stainless steel Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . nylon Suction Tube (236–414 and 236–869) . . . . . . . . . . . acetal

Maximum Fluid Working Pressure

. 100 psi (0.7 MPa, 7 bar)

Air Pressure Operating Range . . .

. . . . . . . . . . . . 15–100 psi

 

(104–700 kPa, 1–7 bar)

Pump Air Inlet Size

. . . . . . . . . . . . . . 1/4 npt(f)

Pump Fluid Inlet and Outlet Size. .

. . . . . . . . . . . . . . 3/8 npt(f)

* Sound Data

 

Pump sound level at 100 psi (0.7 MPa, 7 bar), full flow

Pump. . . . . .sound. . . . . .level. . . .at. . 70. . .psi. . .(480. . . . .kPa,. . . . 4.8. . . .bar),

85 dB(A)

 

1 gpm (3.8 lpm)

78 dB(A)

Operating Temperature Range: 40_ to 150_F (4.4_ to 65.5_C)

* Tested to CAGI-PNEUROP–1969

PTFE is a registered trademark of the Du Pont Co.

Manual Change Summary

This manual was revised to include the changes from PCN J.

3￿8￿23￿ 19

Image 19
Contents 308-230 Symbols Table of ContentsToxic Fluid Hazard Assembling Pail Mount Units InstallationAssembling the Wall Mount Unit General Information AccessoriesHose Connections KEY Air Spray Typical Installation Grounding Flush the Pump Before First Use Pressure Relief ProcedureStarting and Adjusting the Pump OperationSurge Tank Models 236-628, 236-869, 236-412, 236-868, Pump ShutdownFlushing and Storage Recirculation LineIncludes items Parts13a Part of item 17a 17b 34 Ref Includes items 1-35 Ref. No , Hose Kit Includes Items Includes items 1-26 13a Wall Mounting Hole Layout DimensionsManual Change Summary Technical DataGraco Phone Number Graco Warranty and Disclaimers