Graco Inc 306706W, 231063 Connecting the Unit and Accessories, elevator, pump, agitator, Detail A

Page 7
Connecting the Unit and Accessories

Installation

The installation shown in Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs.

Connecting the Unit and Accessories

DGround the unit as described in Grounding on page 6.

DConnect a 1/2 in. (13 mm) minimum ID, grounded air supply hose to the 1/2 in. npt(f) air inlet swivel (32).

DThe main air supply must include a bleed-type master air valve (A) for shutting off air pressure to the unit.

DThe fluid line must include a fluid drain valve (not shown), which helps relieve fluid pressure in the hose and gun.

DYou should install an air line filter (B) to remove dirt and moisture from the air supply.

To order an air line filter, order by Part No. from the list below:

203421 1/2” npt inlet and outlet, with gauge,

200 psi (1.4 MPa, 14 bar) maximum working pressure. See instruction manual 306393.

204856 1/2” npt inlet and outlet, without gauge,

200 psi (1.4 MPa, 14 bar) maximum working pressure. See instruction manual 306393.

DDownstream from the air filter, you should install an air line lubricator (C) for automatic air motor lubrica- tion. To order a 1/2” npt(f) inlet and outlet, 250 psi (1.4 MPa, 14 bar) maximum working pressure airline lubricator, order Part No. 214848. For more information, see instruction manual 307316.

DConnect the fluid hose (7) to the nipple on the outlet filter (17). Do not use thread sealer. Con- nect the spray gun (20) to the swivel (5). See page 10.

B

A

 

 

elevator

 

32

pump

 

 

 

 

agitator

 

C

 

 

 

DETAIL A

 

See DETAIL A

 

 

 

04280

 

 

NOTE: Valve feet must

 

 

contact perforated plate.

 

 

05511

 

Fig. 2

 

 

 

306706

7

Image 7
Contents Model 231063, Series C Instructions-Parts ListImportant Safety Instructions 301 President R Hydra-Spray RStarting and Adjusting the Pump Table of ContentsAdjusting the Unit Installation306706 EQUIPMENT MISUSE HAZARDMOVING PARTS HAZARD SKIN INJECTION HAZARDTOXIC FLUID HAZARD FIRE AND EXPLOSION HAZARDPositioning the Unit InstallationSystem Accessories Groundingpump Connecting the Unit and AccessoriesTo order an air line filter, order by Part No. from the list below elevatorFlushing the Pump Operation/MaintenancePressure Relief Procedure Adjusting the UnitShutdown and Care of the Pump Starting and Adjusting the Pump06218A Parts DrawingModel 231063, Series C, 301 PresidentR Hydra-SprayR 06218SWIVEL See 306861 for parts Parts ListDescription See 306287 for partsPage Technical Data FOR GRACO CANADA CUSTOMERS Graco Standard WarrantyGraco Information GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN